R32 Split Series
INSTALLATION MANUAL
DAIKIN ROOM AIR CONDITIONER
MODELS
FTXJ20LV1BW FTXJ20LV1BS
FTXJ25LV1BW FTXJ25LV1BS
FTXJ35LV1BW FTXJ35LV1BS
FTXJ50LV1BW FTXJ50LV1BS

Questions and Answers

  • K
    Kayla MoranAug 19, 2025
    What to do if my Daikin Air Conditioner has water leakage?
    • J
      Jeremy RobertsAug 19, 2025
      If you notice water leakage from your Daikin Air Conditioner, there are a couple of potential causes: * Incomplete thermal insulation of gas and liquid piping, including indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. * Improperly connected drainage. Make sure to secure the drainage.
  • R
    ronniehayesAug 21, 2025
    What to do if my Daikin FTXJ20LV1BW Air Conditioner unit does NOT function or shows burn damage?
    • C
      Christopher LeeAug 21, 2025
      If your Daikin Air Conditioner unit isn't functioning or shows signs of burn damage, the wiring may not have been performed according to specifications. Correct the wiring to resolve this issue.
  • A
    ashley45Aug 23, 2025
    What to do if the LED is ON on my Daikin FTXJ20LV1BW Air Conditioner?
    • J
      Jeremy FuentesAug 23, 2025
      If the LED is ON, turn the power OFF and then back ON. Check the LED within approximately 3 minutes. If the LED turns ON again, it indicates that the outdoor unit PCB is faulty.
  • D
    daniel58Aug 26, 2025
    Why is my Daikin FTXJ20LV1BW not heating or cooling as expected?
    • T
      Tammy MillerAug 26, 2025
      There are several reasons why your Daikin Air Conditioner might not be heating or cooling properly. It could be due to incorrect connection of the electrical wires, which requires you to connect them correctly. Another potential cause is gas leakage, so check for any signs of leakage. Also, ensure that the marks on the wiring and piping for each indoor unit match (room A, room B, room C, room D, room E).
  • N
    Nicholas HopkinsAug 28, 2025
    What to do if my Daikin Air Conditioner is leaking water?
    • M
      Michael WigginsAug 28, 2025
      If your Daikin Air Conditioner is leaking water, it could be due to incomplete thermal insulation on the gas and liquid piping, as well as the indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. Another possible cause is improperly connected drainage, so make sure to secure the drainage.
  • B
    Brenda CantuAug 30, 2025
    What to do if there's water leakage from my Daikin Air Conditioner?
    • B
      Bryan BradleyAug 31, 2025
      If you notice water leakage from your Daikin Air Conditioner, it could be due to incomplete thermal insulation of the gas and liquid piping, or the indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. Another cause might be improperly connected drainage, so secure the drainage.
  • C
    Calvin WoodardSep 2, 2025
    How to fix Daikin Air Conditioner indoor units that fall, vibrate or make noise?
    • I
      iwilsonSep 2, 2025
      If the indoor units of your Daikin Air Conditioner are falling, vibrating, or making noise, ensure that you install them securely.
  • B
    Bradley WilliamsSep 4, 2025
    Why is the LED OFF on my Daikin FTXJ20LV1BW?
    • A
      Anthony BarreraSep 4, 2025
      The LED might be OFF due to supply voltage issues (related to power saving) or a power supply fault. To resolve this, turn the power OFF and then back ON. Check the LED within approximately 3 minutes. If the LED remains OFF, the outdoor unit PCB is likely faulty.
  • B
    Bethany MillerSep 6, 2025
    How to fix electrical leakage in Daikin Air Conditioner?
    • A
      Amy LopezSep 6, 2025
      If you have electrical leakage in your Daikin Air Conditioner, the unit might not be earthed correctly. Check and correct the connection of the earth wiring.
  • M
    msmithSep 9, 2025
    What to do if there is refrigerant leakage in the room from Daikin Water Heater?
    • D
      David JonesSep 9, 2025
      If you detect refrigerant leakage from your Daikin Water Heater: * Turn off any combustible heating devices. * Ventilate the room. * Contact the dealer where you purchased the unit. Do not use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired.

Daikin FTXJ20LV1BW Specifications

General IconGeneral
Cooling Capacity2.0 kW
Heating Capacity2.5 kW
Seasonal Energy Efficiency Ratio (SEER)6.1
Power Supply220-240V / 50Hz
Indoor Unit Weight11.5 kg
Outdoor Unit Weight26 kg
RefrigerantR-32
Energy Efficiency Class (Cooling)A++
Energy Efficiency Class (Heating)A+
TypeSplit
Outdoor Unit Dimensions (HxWxD)550 x 700 x 275 mm
Noise Level (Indoor)19 dBA
Sound Power Level (Heating)35 dB
Indoor Unit Noise Level19 dBA