4 | Components
Service manual
58
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04 – 2022.04
c
f
b
a d
e
a Power supply terminal X1M
b Power supply wiring bracket
c Screw (ground wire)
d Indoor unit main PCB
e Switch box screw
f Switch box
5 Disconnect the connectors of the indoor unit fan motor and the swing flap
motors from the indoor unit PCB.
6 Detach these wiring harnesses from the switch box.
7 Remove the screw and remove the switch box from the indoor unit.
8 To install the switch box, see "4.1Plate work"[448].
To install the switch box
1 install the switch box in the correct location on the indoor unit.
c
f
b
a d
e
a Power supply terminal X1M
b Power supply wiring bracket
c Screw (ground wire)
d Indoor unit main PCB
e Switch box screw
f Switch box
2 Route the connectors of the indoor unit fan motor and swing flap motors
inside the switch box and connect them to the indoor unit PCB.
3 Install and tighten the screw to secure the switch box.
draft–22/04/2022 08:50