TS13-01 Troubleshooting manual 2
Inverter Air conditioning technology is today’s solution for superior comfort, higher efficiency and better energy
saving. Daikin Inverter included Residential, Light Commercial and Multi Split Unit.
INVERTER Y SINGLE SPLIT (Residential, Light Commercial)
i) INDOORS
ii) OUTDOORS
1.1 INVERTER Y SINGLE SPLIT
Residential (FTXN-LV & RXN-LV):
- High Quality & Efficiency Daikin DC Inverter compressor
- High Performance Daikin Inverter Controller
- 5-speed Step-less Fan operation
- BioPro IAQ.
- New Inverter-only Remote Control
Piping Length & Elevation
Model
Max. total
piping length
(m)
Max. height
difference
(m)
Pre-charge for
up to piping
length (m)
Additional
charge
(g/m)
RXN25LV1B
20
10
7.5
20
RXN30LV1B
20
10
7.5
20
RXN50LV1B
30
10
7.5
20
RXN60LV1B
30
10
7.5
20
Terminal Block for outdoor:
- Equipped with 7-segment display to improve serviceability. (Exclude for RXN25/30LV1B)
- To retrieve error code & running parameters.
1.0 Introduction