SiUS041111 Outdoor Unit: 09/12 Class
Removal Procedure 177
3. Remove the electrical box.
1
Disconnect the
connector for the
overload protector
[S40].
2
Disconnect the
connector for the
four-way valve coil
[S80].
The cooling only model has no
harness for [S80].
3
Disconnect the
connector for the
electronic expansion
valve coil [S20].
Step Procedure Points
[S40]
(R11771)
[S80]
(R11772)
[S20]
(R11773)