Loading...
Si041137 Removal of PCBs (Pattern 1)
Removal Procedure 19
3
The figures show the
names of the PCB
component parts.
[S1]: DC fan motor
[S25]: INTELLIGENT EYE
sensor PCB
[S26]: control PCB
[S32]: indoor heat exchanger
thermistor
[S41]: swing motors
[S46]: display PCB
[S47]: signal receiver PCB
[S48]: control PCB
[S49]: control PCB
Step
Procedure Points
(R16970)
[S32]
[S1]
[S47]
[S25]
[S46]
[S41]
(R8100)
[S48]
[S49]
[S26]
LED2
(Yellow)
LED3
(Green)
LED1
(Green)