Installation and operation manual
Ducted fan coil units
English
Installations- und Bedienungsanleitung
Kanal-Ventilator-Konvektoren
Deutsch
Manuel d’installation et d’utilisation
Ventilo-convecteurs canalisés
Français
Montagehandleiding en gebruiksaanwijzing
Ventilator-convectoren met kanaalaansluiting
Nederlands
Manual de instalación y operación
Fan coils entubados
Español
Manuale d’installazione e d’uso
Unità fan coil canalizzata
Italiano
Εγχειρίδιο εγκατάστασης και χρήσης
Μονάδα διοχέτευσης ανεμιστήρα
Ελληνικά
Manual de instalação e de funcionamento
Ventilo-convectores de conduta
Portugues
Руководство по установке и эксплуатации
Канальный вентиляторный дововодчик
русский
Installations - och bruksanvisningar
Kanalansluten äktkonvektor
Svenskt
FWD
INSTALLATION AND OPERATION MANUAL
Ducted fan coil units
English language: Original Instructions
All other language: Translation of the Original Instruction

Questions and Answers

  • G
    Gloria BrooksAug 8, 2025
    Why is my Daikin FWD16ACTN6V3 Air Conditioner not cooling well?
    • D
      Danielle HenryAug 9, 2025
      Poor cooling or heating performance in your Daikin Air Conditioner can stem from several causes: a dirty or clogged air filter (clean it), an obstacle near the air inlet or outlet (remove it), open doors or windows (close them), or the unit running at low speed (select medium or high fan speed). Also, air inside the heat exchanger can affect performance, so you may need to contact the installer.
  • H
    Heather DavisAug 18, 2025
    How to fix Daikin FWD16ACTN6V3 that won't turn on?
    • S
      smithwendyAug 18, 2025
      If your Daikin Air Conditioner isn't turning on, the issue might be a power failure (restore power), a tripped automatic circuit breaker (contact service center), or the switch being in the STOP position (turn the unit ON by selecting “I”).
  • M
    Michael LewisAug 29, 2025
    What to do if my Daikin FWD16ACTN6V3 Air Conditioner is leaking?
    • L
      Laura JenkinsAug 29, 2025
      If your Daikin Air Conditioner is leaking, it could be due to incorrect installation, specifically the unit not being installed with the correct inclination, or a clogged condensate discharge. In both cases, it's best to contact the installer for assistance.

Summary

Before Installation

Use and Operating Limits

Description of the Equipment

Main components

Details the primary structural and functional parts of the unit.

Dimensions

Intake module with flat filter class EU 2

Provides dimensions for the intake module with a flat EU 2 filter.

Standard unit

Details the dimensional specifications for the standard unit configuration.

Installation

Horizontal or vertical installation

Explains how to install the unit in either horizontal or vertical orientations.

Configuration of the unit

Describes how to change the air inlet position during installation.

Description of the kit

Lists and describes the components included in the installation kit.

Field Wiring

Wiring parts table

Provides a table mapping wire colors to their respective functions.

Maintenance and Cleaning

Maintenance

Outlines routine maintenance tasks and safety precautions.

Cleaning the air filter

Step-by-step guide for cleaning the unit's air filter.

Cleaning the heat exchanger

Instructions for cleaning the internal heat exchanger.

Disposal Requirements

Troubleshooting

Daikin FWD16ACTN6V3 Specifications

General IconGeneral
BrandDaikin
ModelFWD16ACTN6V3
CategoryAir Conditioner
LanguageEnglish