28
Sound Data
Model
(MSP)
Speed
1/1 Octave Sound Pressure Level (dB, reference 20mPa)
Overall
(dBA)
Noise
Criteria
125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
FWC03G
High 37 36 34 30 23 15 5 35 29
Med 32 30 28 24 16 5 5 29 22
Low 24 22 20 12 7 7 6 20 -
FWC04G
High 37 37 36 32 28 21 12 37 31
Med 32 31 30 26 20 12 5 31 24
Low 25 22 22 15 8 5 5 22 -
FWC06G
High 46 41 39 36 30 24 15 41 35
Med 41 37 37 32 25 18 9 37 32
Low 38 32 31 25 17 9 4 31 25
FWC08G
High 47 43 41 38 32 26 15 43 37
Med 43 38 36 32 25 17 6 37 31
Low 37 31 30 24 16 6 5 30 24
FWC10G
High 48 44 42 39 33 26 18 44 38
Med 47 41 38 34 28 20 10 40 33
Low 43 33 32 26 18 7 5 33 26
FWC12G
High 48 44 43 39 33 26 18 44 38
Med 43 40 39 35 29 21 12 40 34
Low 40 38 36 32 24 15 6 37 31
FWC14G
High 52 46 47 41 36 31 26 47 43
Med 48 42 43 36 31 26 19 43 38
Low 41 35 35 28 23 15 7 35 30
FWC16G
High 55 48 47 42 38 34 28 48 43
Med 50 42 44 38 33 28 21 44 39
Low 43 36 38 29 25 17 7 37 33
FWC18G
High 57 51 46 42 38 34 30 49 41
Med 55 45 42 38 36 29 24 45 39
Low 52 39 35 30 26 20 13 39 35
FWC20G
High 55 52 49 43 38 36 31 50 45
Med 52 48 44 39 35 31 26 46 39
Low 46 39 37 31 26 20 13 38 32
Microphone position: 1.5m below the centre of the unit.