Daikin FXMQ-MVE User Manual

Daikin FXMQ-MVE
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
technical data
Systems
Introduction
Question and Answer IconNeed help?

Do you have a question about the Daikin FXMQ-MVE and is the answer not in the manual?

Daikin FXMQ-MVE Specifications

General IconGeneral
SeriesFXMQ-MVE
RefrigerantR-410A
Power Supply220-240 V, 50 Hz
Energy Efficiency Ratio (Cooling)3.5
Energy Efficiency Ratio (Heating)3.8
Outdoor Unit Noise Level50 dB(A)

Summary

VRVII technology

VRVII Technology: Reluctance brushless DC Compressor

Describes the benefits of the reluctance brushless DC compressor for efficiency and power.

VRVII Technology: e-Bridge circuit

Details the SCe-bridge circuit for improved evaporative capacity and COP.

Main features

Main Features: Inverter technology

Details the variable PI control and compressor stages for precise capacity control.

Main Features: Smart control brings comfort

Explains PID control for stable room temperatures and reduced variations.

Main Features: Less frequent start/stop cycle

Discusses capacity regulation with multiple compressors for efficiency and standby.

Main Features: PID control

Details PID control for capacity balancing and long piping lengths.

Main Features: Energy efficient solution

Covers features that reduce energy consumption and operating costs.

Main Features: Low running costs

Explains how individual zone control and high COP/EER reduce operational expenses.

Main Features: Most advanced reluctance brushless DC compressor technology

Highlights the efficiency and performance benefits of the DC compressor.

Main Features: HRV - Heat Recovery Ventilation System

Describes the HRV system for heat/humidity exchange and reduced load.

Main Features: Operation range of outdoor temperature

Specifies the operating temperature limits for cooling and heating modes.

Main Features: High reliability

Covers features that ensure system durability and continuous operation.

Main Features: Double back-up function

Explains the system's redundancy for emergency operation during compressor failure.

Main Features: Special oil equalising technology

Details the oil balancing system for compressor reliability.

Main Features: Eco friendly

Covers environmental aspects, including refrigerant use and material recycling.

Main Features: Optimised R-410A design

Details the system's design using R-410A refrigerant for efficiency and environmental compliance.

Main Features: Easy and flexible design

Highlights adaptability in system design and installation for various layouts.

Main Features: Simple and rapid installation

Covers features that simplify and speed up the installation process.

Selection procedure

Selection Procedure: VRVII System based on cooling load

Guides on selecting indoor and outdoor units based on cooling load calculations.

Selection Procedure: Indoor unit selection

Explains how to select indoor units using capacity tables and load data.

Selection Procedure: Outdoor unit selection

Details selecting outdoor units based on indoor unit combinations and capacity index.

Selection Procedure: Selection example based on cooling load

Walks through an example of selecting units for a cooling load scenario.

Selection Procedure: Capacity correction ratio

Explains how to adjust capacity based on piping length and level differences.

Related product manuals