EasyManua.ls Logo

Daikin Inverter FTXS85LVMA - User Manual

Daikin Inverter FTXS85LVMA
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL
MODELS
FTXS85LVMA
FTXS95LVMA
00_CV_3P291209-3.indd 100_CV_3P291209-3.indd 1 11/30/2011 2:37:19 PM11/30/2011 2:37:19 PM

Questions and Answers

  • A
    Alexander BanksAug 15, 2025
    Why is my Daikin Air Conditioner cooling (heating) effect poor?
    • P
      Paula ReynoldsAug 15, 2025
      Several factors can cause a poor cooling or heating effect. Check if the air filters are clean and ensure that nothing is blocking the air inlet or outlet of either the indoor or outdoor units. Also, verify that the temperature setting is appropriate, and that all windows and doors are closed. Finally, make sure the airflow rate and direction are set correctly.
  • A
    Alexandra JohnsonAug 18, 2025
    How to fix Daikin Inverter FTXS85LVMA Air Conditioner ON/OFF TIMER that is not operating according to the settings?
    • C
      cookandrewAug 18, 2025
      Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.
  • M
    Matthew CooperAug 21, 2025
    What to do if my Daikin Inverter FTXS85LVMA Air Conditioner operation stopped suddenly?
    • D
      Dean EllisAug 21, 2025
      If the OPERATION lamp is flashing, first ensure the air filters are clean. If not, clean them. Check for any obstructions blocking the air inlet or outlet of the indoor and outdoor units; if present, turn off the breaker, remove the obstacles, and then turn the breaker back on. If you are using a multi system, ensure all indoor units are set to the same operation mode. If issues persist, set all indoor unit operation modes to “COOL” or “HEAT” for a moment and check again that the lamps are normal. If the lamps stop flashing after the above steps, there is.
  • K
    Kristin HessAug 25, 2025
    What to do if my Daikin Inverter FTXS85LVMA does not operate?
    • W
      William BarnesAug 25, 2025
      If the OPERATION lamp is off, check the following: ensure that a breaker hasn’t turned off or a fuse hasn’t blown, verify that there isn’t a power failure, confirm that batteries are correctly installed in the remote controller, and ensure the timer setting is correct.
  • M
    Michele LopezAug 27, 2025
    How to fix Daikin Air Conditioner remote controller that is not working properly?
    • W
      Wendy RodriguezAug 27, 2025
      If the remote controller isn't working, it may be due to dying batteries or a malfunction. Replace all the batteries with new, size AAA.LR03 (alkaline) batteries.
  • D
    Diane WatersAug 30, 2025
    Why does hot air not flow out soon after starting heating operation on my Daikin Inverter FTXS85LVMA Air Conditioner?
    • S
      Steven WelchAug 30, 2025
      The air conditioner is warming up. Allow 1 to 4 minutes for hot air to begin flowing.
  • D
    daniel73Sep 2, 2025
    Why does mist come out of my Daikin Inverter FTXS85LVMA Air Conditioner indoor unit?
    • M
      Matthew GlassSep 2, 2025
      Mist may appear from the indoor unit because the air in the room is cooled into mist by the cold airflow during COOL operation. It can also occur because the air in the room is cooled by the heat exchanger and becomes mist during defrosting operation.
  • J
    Judith SmithSep 5, 2025
    What to do if my Daikin Inverter FTXS85LVMA Air Conditioner has an abnormal functioning during operation?
    • G
      gkerrSep 5, 2025
      The air conditioner may malfunction due to lightning or radio waves. To resolve this, turn the breaker off, then turn it back on, and try operating the air conditioner with the remote controller.
  • J
    Juan ReedSep 8, 2025
    Why does the outdoor fan rotate when my Daikin Air Conditioner is not in operation?
    • A
      ashleysotoSep 8, 2025
      The outdoor fan may continue rotating for up to 60 seconds after the air conditioner stops to protect the system. Additionally, when the outdoor temperature is very high, the outdoor fan may start rotating for system protection.
  • M
    Mandy LawrenceSep 12, 2025
    Why does my Daikin Inverter FTXS85LVMA Air Conditioner operation not start soon?
    • I
      iedwardsSep 12, 2025
      You should wait for about 3 minutes.

Summary

Product Features and Functions

Intelligent Eye Sensor

Detects human movement for automatic energy saving operation.

Weekly Timer Function

Enables setting up to 4 daily timers for personalized scheduling.

Comfort Airflow

Directs airflow for optimal comfort in COOL or HEAT modes.

Outdoor Unit Quiet Operation

Reduces outdoor unit noise for quieter operation.

Safety Precautions and Warnings

General Safety Guidelines

Essential warnings and cautions to prevent injury, fire, and property damage.

Operational Safety Rules

Precautions regarding unit operation, electrical safety, and environmental hazards.

Installation and Usage Cautions

Guidelines for safe installation, handling, and usage of the unit.

Component Identification

Indoor Unit Parts

Identification and description of the indoor unit's main components and sensors.

Outdoor Unit Parts

Identification of the outdoor unit's components and connections.

Remote Controller Overview

Details of the remote control's signal transmitter, display, and basic buttons.

Remote Controller Buttons Functionality

Explains the functions of various buttons for mode selection, airflow, and timers.

Getting Started

Remote Controller Setup

Instructions for inserting batteries and mounting the remote controller holder.

Setting the Unit Clock

Guide to setting the internal clock for accurate timer functions.

Operating the Air Conditioner

Selecting Operation Modes

How to start and stop the unit using different operation modes like AUTO, COOL, HEAT.

Adjusting Temperature Settings

Steps to change the desired temperature for cooling and heating operations.

Airflow and Comfort Control

Adjusting Airflow Direction

Setting airflow direction for auto swing, 3D airflow, and desired positions.

Setting Airflow Rate

Selecting desired airflow speed and understanding quiet operation.

Enhanced Comfort and Efficiency

Comfort Airflow Operation

Optimizes airflow direction for user comfort in COOL/HEAT modes.

Intelligent Eye Operation

Automatically adjusts operation based on room occupancy for energy savings.

Combining Comfort and Intelligent Eye

Using both features simultaneously and managing their priority.

Performance Boost

Powerful Operation Mode

Temporarily maximizes cooling or heating output for quick comfort.

Noise Level Management

Outdoor Unit Quiet Mode

Reduces the noise level of the outdoor unit for quieter neighborhood.

Energy Saving Modes

Econo Operation

Limits power consumption to ensure efficient operation and prevent breaker trips.

Timer Programming

Off Timer Operation

Setting the unit to automatically turn off at a specified time.

On Timer Operation

Setting the unit to automatically turn on at a specified time.

Advanced Scheduling Features

Weekly Timer Overview

Setting up to four timer programs per day for a week.

Setting Weekly Timer Programs

Step-by-step guide to define daily schedules for the weekly timer.

Weekly Timer Copy Mode

Copying programmed settings to other days for efficient scheduling.

Confirming and Deactivating Weekly Timer

Checking current timer reservations and disabling the weekly timer.

Deleting Weekly Timer Reservations

Removing individual or all programmed timer settings.

Multi-System Operation Guide

Operation Mode Selection (Multi-System)

Managing operation modes across multiple indoor units connected to one outdoor unit.

Priority Room Setting and Mode Lock

How priority rooms influence operations and the function of mode locks.

Maintenance and Cleaning Procedures

Cleaning Component Guide

Overview of parts to clean and general cleaning notes.

Cleaning the Front Panel

Detailed steps for removing, cleaning, and reattaching the front panel.

Cleaning the Air Filters

Instructions for removing, washing, and maintaining the unit's air filters.

Cleaning the Purifying Filter

Guide to cleaning or replacing the titanium apatite photocatalytic air-purifying filter.

Preparing for Long Idle Periods

Steps for storing the unit during extended periods of non-use.

Troubleshooting Common Issues

Understanding Normal Operation Sounds

Explains common sounds during operation and their causes.

Resolving Operation Stoppages

Addresses issues like unit not operating, sudden stops, and poor heating effect.

Performance and Remote Control Issues

Troubleshooting poor cooling/heating, remote control malfunctions, and unit odors.

Service and Support Information

When to Contact Service

Symptoms requiring professional service and warnings against self-repair.

Remote Controller Fault Codes

Guide to interpreting error codes displayed by the remote controller.

Daikin Inverter FTXS85LVMA Specifications

General IconGeneral
TypeInverter
Cooling Capacity8.5 kW
Heating Capacity9.5 kW
Seasonal Energy Efficiency Ratio (SEER)6.1
Power Supply220-240V, 50Hz
Indoor Unit Dimensions (W x H x D)1100 x 300 x 240 mm
Outdoor Unit Dimensions (W x H x D)800 x 550 x 330 mm
Weight (Indoor Unit)12 kg
Weight (Outdoor Unit)42 kg
Capacity8.5 kW
RefrigerantR32

Related product manuals