Inverter Pair
Wall Mounted Type B-Series
[Applied Models]
z
zz
zInverter Pair : Cooling Only
z
zz
zInverter Pair : Heat Pump
z
zz
zNon-Inverter Pair : Cooling Only
z
zz
zNon-Inverter Pair : Heat Pump
Si04-306
Service
Manual

Table of Contents

Other manuals for Daikin RXD50BVMA

Questions and Answers

  • R
    Ray GrossAug 8, 2025
    Why is my Daikin RXD50BVMA outdoor unit leaking water?
    • A
      Angel StrongAug 8, 2025
      In HEAT mode, frost on the outdoor unit melts into water or steam when the Daikin air conditioner is in defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of outdoor unit piping and drips.
  • A
    Andrew PierceAug 14, 2025
    Why does the outdoor fan on my Daikin RXD50BVMA Air Conditioner keep running when it's not in use?
    • N
      Nicole ReyesAug 14, 2025
      The outdoor fan might continue rotating for an additional 60 seconds to protect the system. Also, when the outdoor temperature is very high, the outdoor fan may start rotating to protect the system.
  • G
    gardnerkelseyAug 20, 2025
    Why is my Daikin RXD50BVMA blowing mist?
    • T
      Thomas HarperAug 21, 2025
      This can occur when the air in the room is cooled into mist by the cold airflow during cooling operation.
  • A
    arnoldrichardAug 27, 2025
    How to get rid of bad smell from Daikin RXD50BVMA Air Conditioner?
    • T
      tonyastoneAug 27, 2025
      If your Daikin Air Conditioner's indoor unit smells, it's recommended to have it cleaned by a qualified technician. Consult the service shop where you bought the air conditioner.
  • J
    Javier MurphySep 1, 2025
    What to do if my Daikin RXD50BVMA stopped suddenly but the operation lamp is on?
    • J
      Joseph JacksonSep 2, 2025
      The Daikin Air Conditioner will automatically resume operation in about 3 minutes.

Summary

Part 1 List of Functions

Part 2 Specifications

1. Specifications

Details the technical specifications, including capacity, power, dimensions, and operating limits.

Part 3 Printed Circuit Board Connector Wiring Diagram

1. Printed Circuit Board Connector Wiring Diagram

Illustrates the connector layout and labeling for both indoor and outdoor unit PCBs.

Part 4 Function and Control

Part 6 Service Diagnosis

1. Caution for Diagnosis

Provides essential cautions and warnings before proceeding with diagnostic procedures.

2. Problem Symptoms and Measures

Lists common operational problems and their corresponding solutions and measures.

4. Troubleshooting

Details error codes, their descriptions, and troubleshooting procedures for system malfunctions.

Part 7 Removal Procedure

Daikin RXD50BVMA Specifications

General IconGeneral
TypeSplit Air Conditioner
Cooling Capacity5.0 kW
Heating Capacity6.0 kW
RefrigerantR32
Power Supply220-240V, 50Hz
Outdoor Unit Noise Level50 dB(A)

Related product manuals