EasyManua.ls Logo

Daikin RXG35CVMB User Manual

Daikin RXG35CVMB
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION
MANUAL
R410A Split Series
Models
RXS20CVMB RKS20CVMB
RXS25CVMB RKS25CVMB
RXS35CVMB RKS35CVMB
ARXS20CVMB ARKS20CVMB
ARXS25CVMB ARKS25CVMB
ARXS35CVMB ARKS35CVMB
RXS20C2VMB RKS20C2VMB
RXS25C2VMB RKS25C2VMB
RXS35C2VMB RKS35C2VMB
ARXS20C2VMB ARKS20C2VMB
ARXS25C2VMB ARKS25C2VMB
ARXS35C2VMB ARKS35C2VMB
RXG25CVMB RXG25E2V1B
RXG35CVMB RXG35E2V1B
ARXG25CVMB ARXG25E2V1B
ARXG35CVMB ARXG35E2V1B
Deutsch
Français
Nederlands
Español
Italiano
ΕλληνικÜ
Portugues
Рóссêий
English
Türkçe
Installation manual
R410A Split series
Montaj kýlavuzlarý
R410A Split serisi
Installationsanleitung
Split-Baureihe R410A
Manuel d’installation
Série split R410A
Montagehandleiding
R410A Split-systeem
Manual de instalación
Serie Split R410A
Manuale d’installazione
Serie Multiambienti R410A
Εγχειρßδιο εγκατÜστασηò
διαιροýìενηò σειρÜò R410A
Manual de Instalação
Série split R410A
Рóêоводство по монтажó
Серия R410A с раздельной óстановêой
00_CV_3P119321-7W.fm Page 1 Thursday, March 8, 2007 5:43 PM

Other manuals for Daikin RXG35CVMB

Questions and Answers:

Daikin RXG35CVMB Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Power Supply220-240 V, 50 Hz
Weight (Indoor Unit)9 kg
Outdoor Unit Noise Level49 dB

Summary

Installation Manual R410A Split Series

Safety Precautions

General Safety Warnings and Cautions

Critical safety warnings and cautions, including symbols, to prevent severe injury or equipment damage.

Accessories Supplied

Precautions for Selecting the Location

Outdoor Unit Location Cautions

Specific guidance for positioning the outdoor unit to avoid wind, snow, and noise issues.

Outdoor Unit Installation Drawings

Installation Guidelines and Precautions

Outdoor Unit Installation Procedures

Essential steps for installing the outdoor unit and performing necessary drain work.

Refrigerant Piping and Connections

Pipe Flaring and Preparation

Detailed instructions on how to flare pipe ends correctly for secure refrigerant connections.

Purging Air and Checking Gas Leakage

Facility Setting for Low Temperature Operation

Instructions for enabling the facility setting to operate the unit in low outdoor temperatures.

Refilling Refrigerant and Piping Work

Refrigerant Piping Handling and Materials

Best practices for handling refrigerant piping and selecting appropriate insulation materials.

Pump Down Operation

Facility Setting

Wiring Procedures

Test Run and Final Check

Trial Operation and Testing Procedures

Steps to conduct trial operations and verify the unit's functionality after installation.

Key Test Items and Symptoms

A checklist of critical tests and expected symptoms to confirm correct installation and operation.

Related product manuals