Daikin RXJ50N2V1B - User Manual

Daikin RXJ50N2V1B
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installer reference guide
R32 split series
RXF50B2V1B
RXF60B2V1B
RXF71A2V1B
ARXF50A2V1B
ARXF60A2V1B
ARXF71A2V1B
RXP50M2V1B
RXP60M2V1B
RXP71M2V1B
ARXM50R2V1B
ARXM60R2V1B
ARXM71R2V1B
RXM42R2V1B
RXM50R2V1B
RXM60R2V1B
RXM71R2V1B
RXJ50N2V1B
RXA42B2V1B
RXA50B2V1B

Table of Contents

Other manuals for Daikin RXJ50N2V1B

Questions and Answers

  • J
    Jennifer GregoryJul 25, 2025
    What to do if my Daikin RXJ50N2V1B has water leakage?
    • A
      Alejandro FitzgeraldJul 25, 2025
      If you notice water leakage from your Daikin Air Conditioner, there are a couple of potential causes: * Incomplete thermal insulation of gas and liquid piping, including indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. * Improperly connected drainage. Make sure to secure the drainage.
  • Z
    Zachary AdamsJul 30, 2025
    What to do if my Daikin RXJ50N2V1B Air Conditioner unit does NOT function or shows burn damage?
    • A
      Alejandro AndersonJul 30, 2025
      If your Daikin Air Conditioner unit isn't functioning or shows signs of burn damage, the wiring may not have been performed according to specifications. Correct the wiring to resolve this issue.
  • E
    Eric GonzalezAug 2, 2025
    Why is my Daikin Air Conditioner not heating or cooling as expected?
    • A
      Angela CampbellAug 2, 2025
      Your Daikin Air Conditioner might not be heating or cooling as expected due to a few reasons. It could be due to incorrect connection of the electrical wires, in which case you should connect the electrical wires correctly. Another potential cause is gas leakage, so check for any gas leakage.
  • A
    andrew26Aug 7, 2025
    What to do if there's water leakage from my Daikin RXJ50N2V1B Air Conditioner?
    • M
      Mark DixonAug 7, 2025
      If you notice water leakage from your Daikin Air Conditioner, it could be due to incomplete thermal insulation of the gas and liquid piping, or the indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. Another cause might be improperly connected drainage, so secure the drainage.
  • D
    Danielle OliverAug 11, 2025
    How to fix Daikin Air Conditioner indoor units that fall, vibrate or make noise?
    • K
      Katie RiceAug 11, 2025
      If the indoor units of your Daikin Air Conditioner are falling, vibrating, or making noise, ensure that you install them securely.
  • F
    Faith JohnsonAug 16, 2025
    What to do if my Daikin Air Conditioner has electrical leakage?
    • T
      Tammy RoseAug 16, 2025
      If you're experiencing electrical leakage with your Daikin Air Conditioner, it's likely that the unit isn't earthed correctly. Check and correct the connection of the earth wiring.
  • E
    Elizabeth PetersonAug 20, 2025
    What to do if I suspect electrical leakage from my Daikin Air Conditioner?
    • A
      awebbAug 20, 2025
      If you suspect electrical leakage from your Daikin Air Conditioner, it's likely that the unit is not earthed correctly. Check and correct the connection of the earth wiring.

Summary

General safety precautions

Refrigerant

Safety measures and regulations for handling refrigerants.

Electrical

Critical electrical safety instructions for installation.

Specific installer safety instructions

Unit installation

Safety guidelines for the installation of the unit.

Charging refrigerant

Safety warnings during refrigerant charging.

Electrical installation

Safety guidelines for electrical connections.

Maintenance and service

Safety precautions for performing maintenance tasks.

Troubleshooting

Safety measures to follow during troubleshooting.

Unit installation

Piping installation

Preparing refrigerant piping

Initial steps and requirements for refrigerant piping.

Refrigerant piping requirements

Specifies materials and diameter for refrigerant pipes.

Connecting the refrigerant piping

Procedures and precautions for connecting refrigerant pipes.

Precautions when connecting the refrigerant piping

Crucial safety warnings for connecting pipes.

Checking the refrigerant piping

Procedures for leak testing and vacuum drying.

Charging refrigerant

About the refrigerant

Information on R32 refrigerant properties and safety.

Electrical installation

Precautions when connecting the electrical wiring

Safety warnings for electrical wiring.

Finishing the outdoor unit installation

Configuration

Commissioning

Precautions when commissioning

Safety warnings before starting commissioning.

To perform a test run

How to conduct a test run to verify system operation.

Maintenance and service

Troubleshooting

Disposal

Technical data

Daikin RXJ50N2V1B Specifications

General IconGeneral
ModelRXJ50N2V1B
CategoryAir Conditioner
TypeSplit System
Cooling Capacity5.0 kW
Heating Capacity5.8 kW
RefrigerantR32
Outdoor Unit Noise Level49 dB(A)
Outdoor Unit Weight34 kg
Power Supply220-240 V, 50 Hz