Summary

1 About the Documentation

1.1 About This Document

This document details installation instructions specific to the outdoor unit.

2 General Safety Precautions

2.1 Documentation Overview and Symbols

Explains warnings, symbols, and general safety precautions.

2.2 For the Installer: General Safety

Provides general safety advice and precautions for installers.

2.2.2 Installation Site Safety

Details requirements for selecting a safe and suitable installation site.

2.2.5 Water and 2.2.6 Electrical Safety

Safety precautions for water and electrical components.

Installation Space Requirements

Specifies minimum floor area requirements based on refrigerant charge.

2.2.3 Refrigerant Safety

Safety precautions related to refrigerant handling.

2.2.4 Brine Safety

Safety precautions for handling brine.

2.2.5 Water Safety

Safety precautions related to water.

2.2.6 Electrical Safety

Safety precautions related to electrical installations.

Electrical Wiring Safety

Precautions for safe electrical wiring practices.

Three-Phase Power Supply Safety

Safety considerations for three-phase power supply.

3 Specific Installer Safety Instructions

Unit Installation Safety

Safety guidelines for installing the unit.

Installation Site Safety

Safety precautions for the installation site.

Refrigerant Piping Connection Safety

Safety precautions for connecting refrigerant piping.

Charging Refrigerant Safety

Safety measures for charging refrigerant.

Electrical Installation Safety

Safety guidelines for electrical installation.

Power Supply and Connector Safety

Safety for power supply and connectors.

Configuration and Commissioning Safety

Safety during configuration and commissioning.

Maintenance and Service Safety

Safety precautions for maintenance and service.

Troubleshooting Safety

Safety measures during troubleshooting.

Switch Box Inspection Safety

Safety when inspecting the switch box.

Thermal Cut-out Safety

Precautions regarding thermal cut-out resets.

4 About the Box

4.1 Overview and Unpacking the Outdoor Unit

Information on handling the box and unpacking the outdoor unit.

4.2.2 Removing Outdoor Unit Accessories

Steps to remove accessories from the outdoor unit packaging.

Accessory Identification

Identification and description of unit accessories.

5 About the Unit

5.2 Unit Identification

Location and purpose of the unit's identification label.

6 Unit Installation

6.1 Preparing the Installation Site

Guidelines for preparing the installation location.

6.1.1 Outdoor Unit Installation Site Requirements

Specific requirements and spacing guidelines for the outdoor unit's site.

Installation Location Restrictions and Seaside Installation

Places to avoid and precautions for seaside installation.

6.1.2 Cold Climate Installation Requirements

Special site requirements for cold climates like snow protection.

6.2 Opening and Closing the Unit

Procedures for opening and closing the unit covers.

6.3 Mounting the Outdoor Unit

Steps, precautions, and structure for mounting the outdoor unit.

6.3.4 Outdoor Unit Installation and Drainage

Steps for installing the unit and ensuring proper condensate drainage.

6.3.5 Drainage in Cold Climates and Drain Socket Installation

Precautions for drainage in cold areas and installing drain sockets.

6.3.6 Securing the Unit Against Wind

Methods to secure the unit against strong winds.

7 Piping Installation

7.1 Preparing Refrigerant Piping

Requirements for preparing refrigerant piping.

7.1.1 Refrigerant Piping Requirements

Specifies material, flare connections, and piping diameter.

7.1.2 Refrigerant Piping Insulation

Guidelines for insulating refrigerant piping.

7.1.3 Refrigerant Piping Length and Height Difference

Maximum allowable pipe length and height difference.

7.2 Connecting the Refrigerant Piping

Procedures and precautions for connecting refrigerant piping.

7.2.1 About Connecting Refrigerant Piping

Typical workflow for connecting refrigerant piping.

7.2.2 Precautions When Connecting Refrigerant Piping

Safety and handling precautions for connecting piping.

7.2.3 Guidelines When Connecting Refrigerant Piping

Best practices for connecting refrigerant pipes.

7.2.4 Pipe Bending Guidelines

Instructions for bending refrigerant pipes.

7.2.5 Flaring the Pipe End

Steps and precautions for flaring pipe ends.

7.2.6 Using the Stop Valve and Service Port

Procedures for handling stop valves and service ports.

7.2.7 Connecting Refrigerant Piping to Outdoor Unit

Connecting liquid and gas piping to the outdoor unit.

7.3 Checking the Refrigerant Piping

Procedures, precautions, and overview for checking refrigerant piping.

7.3.3 Leak Detection and 7.3.4 Vacuum Drying

Steps for leak detection and vacuum drying refrigerant piping.

8 Charging Refrigerant

8.1 About Charging Refrigerant

Explains when additional or complete recharging is necessary and the workflow.

8.2 About the Refrigerant

Information about R32 refrigerant type and its properties.

8.3 Precautions, Additional Amount, and Total Charge

Precautions, calculation for additional, and total refrigerant amounts.

8.6 Charging Additional Refrigerant and Fixing Label

Steps for charging refrigerant and affixing the gases label.

9 Electrical Installation

9.1 Connecting the Electrical Wiring

Overview and safety precautions for connecting electrical wiring.

9.1.2 Guidelines When Connecting Electrical Wiring

Best practices for connecting electrical wires.

9.1.3 Specifications of Standard Wiring Components

Details on wire types, sizes, and tightening torques.

9.2 Connecting Electrical Wiring to Outdoor Unit

Step-by-step guide to connecting wiring to the outdoor unit, including terminal tightening.

10 Finishing the Outdoor Unit Installation

10.1 Finishing Steps and Closing the Unit

Finalizing installation, insulating piping, and closing the unit cover.

11 Configuration

Facility Setting and Standby Electricity Saving

How to set facility mode and use standby electricity saving function.

11.2.2 Turning On Standby Electricity Saving

Steps to activate the standby electricity saving feature.

12 Commissioning

12.1 Precautions and 12.2 Checklist Before Commissioning

Safety precautions and pre-commissioning checks for the unit.

12.3 Commissioning Checklists and 12.4 Test Run

Checklists and steps for performing a test run.

12.5 Starting Up the Outdoor Unit

Final steps for starting up the outdoor unit.

13 Hand-over to the User

User Hand-over Procedures

Explaining operation, maintenance, and energy saving to the user.

14 Maintenance and Service

14.1 Overview and Safety Precautions

Introduction to maintenance and safety guidelines.

14.3 Yearly Maintenance Checklist

Items to check during yearly maintenance.

14.4 Compressor Service Precautions

Safety precautions for servicing the compressor.

15 Troubleshooting

15.1 Overview and 15.2 Precautions

Introduction to troubleshooting and safety warnings.

15.3 Problem Solving by Symptom and 15.4 LED Diagnosis

Troubleshooting common issues and diagnosing faults using LEDs.

16 Disposal

16.1 Overview and 16.2 Pump Down Procedure

General disposal guidelines and steps for pumping down refrigerant.

16.3 Starting and Stopping Forced Cooling

Methods for performing forced cooling.

17 Technical Data

17.1 Wiring Diagram Legend

Explanation of symbols, colors, and components in wiring diagrams.

Wiring Diagram Symbols (Continued)

Further explanation of symbols used in wiring diagrams.

17.2 Piping Diagram: Outdoor Unit

Specific piping diagram for RXP50M, RXF50B, ARXF50A models.

Piping Diagram: Specific Models (RXP60M to ARXF71A)

Piping diagrams for various RXP, RXF, ARXF models.

Piping Diagram: Specific Models (RXJ50N, ARXM71R)

Piping diagrams for RXJ50N and ARXM71R models.

Piping Diagram: Specific Models (RXM42R, RXM50R, ARXM50R)

Piping diagrams for RXM42R, RXM50R, ARXM50R models.

18 Glossary

Glossary of Terms

Definitions of terms used in the manual.

Related product manuals