REMOVAL
PROCEDURE
SERVICE MANUAL
4.6/5.0/6.0/7.1 kW Class
Outdoor Unit
Inverter
Pair Type
Si001654EA
Question and Answer IconNeed help?

Do you have a question about the Daikin RXM60QVMA and is the answer not in the manual?

Daikin RXM60QVMA Specifications

General IconGeneral
BrandDaikin
ModelRXM60QVMA
CategoryAir Conditioner
LanguageEnglish

Summary

Outer Panels Removal

Top Panel Removal

Procedure to remove the top panel by unscrewing 6 screws.

Outdoor Fan and Fan Motor Removal

Outdoor Fan Removal

Procedure to remove the outdoor fan by unscrewing the nut.

Fan Motor Removal

Procedure to remove the fan motor by unscrewing.

Thermistor Assembly and PCB Removal

Main PCB Removal

Procedure to remove the main PCB by unscrewing and unfastening hooks.

Four Way Valve and Expansion Valve Removal

Four Way Valve Coil Removal

Procedure to remove the four way valve coil by unscrewing.

Electronic Expansion Valve Coil Removal

Procedure to remove the electronic expansion valve coil.

Four Way Valve Removal (Heating)

Procedure to remove the four way valve by removing putty and heating brazed parts.

Compressor Removal Procedure

Disconnect Compressor Wiring and Pipes

Procedure to disconnect compressor lead wires, overload protector, and heat brazed pipes.

Final Compressor Removal

Procedure to remove the compressor by unscrewing nuts after disconnecting pipes.