Installer reference guide
R32 split series
ARXM50N2V1B9
ARXM60N2V1B9
ARXM71N2V1B9
RXM42N2V1B9
RXM50N2V1B9
RXM60N2V1B9
RXM71N2V1B
RXP50M2V1B
RXP60M2V1B
RXP71M2V1B
RXA42B2V1B
RXA50B2V1B
RXF50B2V1B
RXF60B2V1B
RXF71A2V1B
RXJ50N2V1B
ARXF50A2V1B
ARXF60A2V1B
ARXF71A2V1B

Table of Contents

Other manuals for Daikin RXM71N2V1B

Questions and Answers

  • M
    Michelle HansenAug 5, 2025
    What to do if my Daikin RXM71N2V1B Air Conditioner has water leakage?
    • C
      Carla BurtonAug 5, 2025
      If you notice water leakage from your Daikin Air Conditioner, there are a couple of potential causes: * Incomplete thermal insulation of gas and liquid piping, including indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. * Improperly connected drainage. Make sure to secure the drainage.
  • L
    Lacey WilsonAug 9, 2025
    What to do if my Daikin RXM71N2V1B Air Conditioner unit does NOT function or shows burn damage?
    • L
      Lauren GarrettAug 9, 2025
      If your Daikin Air Conditioner unit isn't functioning or shows signs of burn damage, the wiring may not have been performed according to specifications. Correct the wiring to resolve this issue.
  • C
    Charles PerezAug 13, 2025
    Why is my Daikin Air Conditioner not heating or cooling as expected?
    • J
      Jennifer CarrAug 13, 2025
      Your Daikin Air Conditioner might not be heating or cooling as expected due to a few reasons. It could be due to incorrect connection of the electrical wires, in which case you should connect the electrical wires correctly. Another potential cause is gas leakage, so check for any gas leakage.
  • M
    margaretdoughertyAug 18, 2025
    What to do if there's water leakage from my Daikin RXM71N2V1B?
    • J
      jason82Aug 18, 2025
      If you notice water leakage from your Daikin Air Conditioner, it could be due to incomplete thermal insulation of the gas and liquid piping, or the indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. Another cause might be improperly connected drainage, so secure the drainage.
  • C
    Christopher GuerreroAug 22, 2025
    How to fix Daikin RXM71N2V1B indoor units that fall, vibrate or make noise?
    • M
      michaelrussellAug 22, 2025
      If the indoor units of your Daikin Air Conditioner are falling, vibrating, or making noise, ensure that you install them securely.
  • J
    James TurnerAug 26, 2025
    What to do if my Daikin Air Conditioner has electrical leakage?
    • B
      barnesdonaldAug 27, 2025
      If you're experiencing electrical leakage with your Daikin Air Conditioner, it's likely that the unit isn't earthed correctly. Check and correct the connection of the earth wiring.
  • A
    Ashley SullivanAug 30, 2025
    What to do if I suspect electrical leakage from my Daikin RXM71N2V1B Air Conditioner?
    • B
      Barry BrownAug 30, 2025
      If you suspect electrical leakage from your Daikin Air Conditioner, it's likely that the unit is not earthed correctly. Check and correct the connection of the earth wiring.

Summary

General Safety Precautions

Installer Safety Precautions and Warnings

Crucial safety guidelines and warnings for installers during installation.

Preparation

Installation Site Requirements

Guidelines for selecting and preparing the installation location for the unit.

Installation

Mounting the Outdoor Unit

Procedures and precautions for securely mounting the outdoor unit.

Connecting Refrigerant Piping

Guidelines and precautions for connecting refrigerant lines.

Checking Refrigerant Piping

Steps for leak testing and vacuum drying the refrigerant piping.

Refrigerant Charging Procedures

Instructions for adding or recharging refrigerant in the system.

Connecting Electrical Wiring

Safety and procedures for connecting the unit's electrical wiring.

Finishing Outdoor Unit Installation

Final steps for completing the outdoor unit installation.

Configuration

Commissioning

Performing a System Test Run

Steps and guidelines for conducting a system test run.

Hand-over to the User

Maintenance and Service

Maintenance Safety Precautions

Critical safety measures to follow before performing maintenance.

Troubleshooting

Troubleshooting Safety Precautions

Important safety warnings to follow during troubleshooting.

Symptom-Based Troubleshooting

Solutions for common problems categorized by symptoms.

Technical Data

Daikin RXM71N2V1B Specifications

General IconGeneral
BrandDaikin
ModelRXM71N2V1B
CategoryAir Conditioner
LanguageEnglish