Do you have a question about the Daikin RY50GAV1A and is the answer not in the manual?
Model Number | RY50GAV1A |
---|---|
Category | Air Conditioner |
Type | Split System |
Cooling Capacity | 5.0 kW |
Heating Capacity | 5.6 kW |
Energy Efficiency Ratio (EER) | 3.21 |
Coefficient of Performance (Heating) | 3.61 |
Power Supply | 220-240V, 50Hz |
Refrigerant | R410A |
Indoor Unit Weight | 13 kg |
Details troubleshooting steps for when the equipment fails to operate.
Addresses the issue where the indoor fan runs, but the compressor does not.
Troubleshooting for cooling/heating operations that start and then stop abruptly.
Addresses issues with restarting the unit after it has shut down.
Troubleshooting steps for when the equipment operates but fails to provide cooling.
Troubleshooting steps for when the equipment operates but fails to provide heating.
Details the procedure for performing self-diagnosis using the remote controller.
Lists and describes various error codes encountered with indoor units.
Provides detailed explanations and diagnostic steps for specific error codes.
Troubleshooting indoor unit PCB abnormalities.
Troubleshooting drain water level system abnormalities.
Troubleshooting indoor unit fan motor abnormalities.
Troubleshooting compressor motor lock issues.
Troubleshooting swing flap motor abnormalities or locks.
Troubleshooting abnormal power supply voltage.
Troubleshooting electronic expansion valve coil abnormalities.
Troubleshooting drain system abnormalities.
Troubleshooting when the drain level is above the limit.
Troubleshooting high pressure system abnormalities.
Addresses abnormally high pressure levels (HPS).
Troubleshooting high pressure abnormalities (HPS).
Addresses actuation of the high pressure switch.
Troubleshooting low pressure system abnormalities.
Addresses actuation of pressure sensors.
Addresses actuation of low pressure sensors.
Troubleshooting low pressure system abnormalities.
Troubleshooting compressor motor lock issues.
Troubleshooting compressor overcurrent issues.
Troubleshooting abnormalities with the outdoor unit fan motor.
Troubleshooting abnormalities with the electronic expansion valve.
Troubleshooting abnormalities with the electronic expansion valve coil.
Troubleshooting abnormalities in discharge pipe temperature.
Addresses control of discharge pipe temperature.
Troubleshooting abnormal heat exchanging temperatures.
Troubleshooting issues related to refrigerant overcharging.
Troubleshooting abnormalities with the high pressure switch.
Troubleshooting abnormalities in the high pressure switch system.
Troubleshooting abnormalities in the low pressure sensor system.
Troubleshooting abnormalities in the outdoor unit fan motor signal.
Troubleshooting abnormalities in thermistor systems J3, J5, J6, J7, J8, H9.
Troubleshooting abnormalities with the outdoor unit PCB.
Troubleshooting abnormalities with the outdoor inverter PCB.
Troubleshooting abnormalities with the outdoor unit PCB.