Do you have a question about the Daikin RZASG71M2V1B and is the answer not in the manual?
Requirements for refrigerant piping, including material, grade, thickness, and diameter.
General information, precautions, and specifications for preparing electrical wiring.
Steps and precautions for mounting the outdoor unit, including structure provision and drainage.
Detailed procedures and precautions for connecting refrigerant piping between indoor and outdoor units.
Procedures for checking external refrigerant piping for leaks and performing vacuum drying.
Information on when and how to charge refrigerant, including safety precautions and amounts.
Procedures and precautions for connecting electrical wiring to the outdoor and indoor units.
Final steps to complete the outdoor unit installation, including insulation and cover reattachment.
Important safety precautions and notices to be aware of before and during the commissioning process.
Step-by-step instructions for performing a test run using the user interface.
Essential safety precautions to follow before performing any maintenance or service work.
Requirements for refrigerant piping, including material, grade, thickness, and diameter.
General information, precautions, and specifications for preparing electrical wiring.
Steps and precautions for mounting the outdoor unit, including structure provision and drainage.
Detailed procedures and precautions for connecting refrigerant piping between indoor and outdoor units.
Procedures for checking external refrigerant piping for leaks and performing vacuum drying.
Information on when and how to charge refrigerant, including safety precautions and amounts.
Procedures and precautions for connecting electrical wiring to the outdoor and indoor units.
Final steps to complete the outdoor unit installation, including insulation and cover reattachment.
Important safety precautions and notices to be aware of before and during the commissioning process.
Step-by-step instructions for performing a test run using the user interface.
Essential safety precautions to follow before performing any maintenance or service work.
| Cooling Capacity | 7.1 kW |
|---|---|
| Heating Capacity | 8.0 kW |
| Energy Efficiency Ratio (EER) | 3.21 |
| Refrigerant | R32 |
| Indoor Unit Dimensions (W x H x D) | 298 x 990 x 292 mm |
| Outdoor Unit Dimensions (W x H x D) | 870 x 765 x 320 mm |
| COP | 3.71 |
| Energy Efficiency Ratio (Cooling) | 3.21 |
| Power Supply | 220-240V / 1 Phase / 50Hz |