Do you have a question about the Daikin RZQ24TAVJU and is the answer not in the manual?
Type | Ducted |
---|---|
Cooling Capacity | 24000 BTU/h |
Heating Capacity | 27000 BTU/h |
Indoor Unit Dimensions (W x H x D) | 700 x 250 x 700 mm |
Outdoor Unit Dimensions (W x H x D) | 800 x 600 x 300 mm |
Phase | 1 |
Refrigerant | R32 |
SEER | 6.2 |
Indoor Unit Weight | 30 kg |
Outdoor Unit Weight | 35 kg |
Voltage (V) | 220-240V |
Explains the meaning of DANGER, WARNING, CAUTION, and NOTE symbols used in the manual.
Details operating conditions and limits for cooling and heating modes.
Lists and illustrates standard accessories included with the unit.
Provides instructions for safely moving the unit during installation.
Defines general criteria for selecting an optimal installation location for the unit.
Provides guidance for installing the unit in windy locations to prevent performance issues.
Outlines precautions for installing the unit in areas prone to heavy snowfall.
Details clearance requirements when obstacles are only in front of the air inlet.
Details clearance requirements when obstacles are only in front of the outlet side.
Details clearance requirements when obstacles are in front of both inlet and outlet.
Specifies space requirements for stacked outdoor unit installations.
Outlines space requirements for multiple-row outdoor unit installations.
Provides instructions for installing drain pipes to prevent freezing and water issues.
Details the procedure for removing transport brackets from specific unit types.
Lists specialized tools required for R410A refrigerant systems.
Specifies suitable materials and thickness for refrigerant piping.
Provides methods to prevent moisture and dirt ingress into piping.
Explains procedures for flare nut connections and brazing.
Details pipe connection methods, including larger diameter pipes.
Recommends insulation dimensions and procedures for piping.
Details the process for testing pipe system integrity and removing moisture.
Illustrates a typical wiring setup for the entire system.
Explains routing and securing power and transmission wiring.
Details the procedure for connecting power supply wiring to the terminal block.
Describes how to connect transmission wiring, including length precautions.
Lists checks required before starting refrigerant charging.
Explains how to check and position the refrigerant tank for charging.
Provides safety warnings and instructions for adding refrigerant.
Details calculating the correct refrigerant amount and the charging process.
Covers essential checks like stop valves, insulation, and recording added refrigerant.
Details the procedure for initial power-up and system check.
Provides a checklist for verifying temperature control during normal operation.
Explains how to fine-tune refrigerant charge for optimal performance.
Details Basic, Automatic, and Hi-sensible cooling operation methods.
Explains comfort settings like Powerful, Quick, Mild, and Eco.
Details how to set heat pump lockout and emergency heat modes.
Sets the outdoor temperature threshold for locking out the heat pump.
Defines the temperature differential for resuming heat pump operation.
Explains auto backup function for auxiliary or secondary heat sources.
Explains how to determine the maximum allowable refrigerant concentration.
Details steps to calculate and check refrigerant concentration levels.