EDUS121131 Capacity Tables
SUPER MULTI NX 2/3/4MXS-G/J Series Heat Pump 211
1
7.4 Capacity Correction Factor by the Length of Refrigerant Piping (Reference)
The cooling capacity and the heating capacity of the unit have to be corrected in accordance with the length of
refrigerant piping — the distance between the indoor unit and the outdoor unit.
<— line: Cooling capacity>
<--- line: Heating capacity>
Note: 1. The graph shows the factor when additional refrigerant of the proper quantity is charged.
2. The variation of the capacity will be smaller when only one indoor unit is in operation.
Capacity correction factor
1
16.4 32.8 49.2 65.6 82.0 (ft)
5 10 15 20 25 (m)
0.9
0.8
R-410A (07/09/12/15/18 class)
Piping length
(R17416)