Capacity Tables EDUS121131
94 SUPER MULTI NX 2/3/4MXS-G/J Series Heat Pump
3D078972 ~ 3D078979
3D078980 ~ 3D078987
CTXS12H +
FDXS12L +
CDXS15L
68.0 26.94 2.11 28.16 2.15 29.37 2.20 29.97 2.22 31.79 2.28 33.00 2.32
77.0 25.72 2.24 26.93 2.28 28.14 2.32 28.75 2.34 30.57 2.41 31.78 2.45
86.0 24.50 2.38 25.71 2.42 26.92 2.46 27.52 2.48 29.34 2.55 30.55 2.59
89.6 24.01 2.44 25.22 2.48 26.43 2.52 27.03 2.54 28.85 2.60 30.06 2.65
95.0 23.27 2.53 24.48 2.57 25.69 2.61
26.30 2.63 28.12 2.70 29.33 2.74
104.0 21.66 2.56 22.70 2.56 23.71 2.56 24.20 2.56 25.65 2.56 26.59 2.56
109.4 17.23 1.77 17.94 1.77 18.63 1.77 18.97 1.77 19.97 1.77 20.62 1.77
114.8 10.85 0.98 11.24 0.98 11.62 0.98 11.81 0.98 12.36 0.98 12.72 0.98
FDXS12L +
FDXS12L +
FTXS15L
68.0 26.94 2.08 28.16 2.12 29.37 2.16 29.97 2.18 31.79 2.25 33.00 2.29
77.0 25.72 2.20 26.93 2.25 28.14 2.29 28.75 2.31 30.57 2.37 31.78 2.41
86.0 24.50 2.34 25.71 2.38 26.92 2.42 27.52 2.45 29.34 2.51 30.55 2.55
89.6 24.01 2.40 25.22 2.44 26.43 2.48 27.03 2.50 28.85 2.56 30.06 2.61
95.0 23.27 2.49 24.48 2.53 25.69 2.57
26.30 2.59 28.12 2.65 29.33 2.70
104.0 21.77 2.56 22.82 2.56 23.83 2.56 24.33 2.56 25.80 2.56 26.74 2.56
109.4 17.28 1.77 18.00 1.77 18.70 1.77 19.04 1.77 20.05 1.77 20.70 1.77
114.8 10.87 0.98 11.26 0.98 11.65 0.98 11.83 0.98 12.39 0.98 12.75 0.98
FDXS12L +
FDXS12L +
CDXS15L
68.0 26.53 2.18 27.73 2.22 28.92 2.26 29.52 2.28 31.31 2.35 32.50 2.39
77.0 25.33 2.31 26.52 2.35 27.72 2.39 28.31 2.42 30.10 2.48 31.30 2.52
86.0 24.12 2.45 25.32 2.49 26.51 2.54 27.11 2.56 28.90 2.62 30.09 2.67
89.6 23.64 2.51 24.83 2.55 26.03 2.60 26.62 2.62 28.41 2.68 29.61 2.73
95.0 22.92 2.60 24.11 2.65 25.30 2.69
25.90 2.71 27.69 2.78 28.88 2.82
104.0 21.16 2.56 22.17 2.56 23.15 2.56 23.63 2.56 25.04 2.56 25.96 2.56
109.4 16.93 1.77 17.62 1.77 18.30 1.77 18.63 1.77 19.60 1.77 20.23 1.77
114.8 10.71 0.98 11.09 0.98 11.47 0.98 11.65 0.98 12.19 0.98 12.53 0.98
Combination
(Capacity)
Outdoor air
temp.
EDB (°F)
Indoor air temp. EWB (°F)
57.2 60.8 64.4 67.0 71.6 75.2
TC PI TC PI TC PI TC PI TC PI TC PI
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW
Symbols: Note:
EWB : Entering wet bulb temp. (°F) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC and PI must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for
calculation.)
4. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft
EDB : Entering dry bulb temp. (°F)
TC : Total capacity (kBtu/h)
PI : Power input (kW)