EasyManua.ls Logo

Daikin SUPER MULTI NX FDXS09LVJU - Page 19

Daikin SUPER MULTI NX FDXS09LVJU
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications EDUS121131
14 SUPER MULTI NX 2/3/4MXS-G/J Series Heat Pump
Cooling [60 Hz, 230 V]
Heating [60 Hz, 230 V]
Note:
1. Cooling capacity is based on 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) (Indoor temperature), 95°FDB
(35°CDB) / 75°FWB (24°CWB) (Outdoor temperature).
Heating capacity is based on 70°FDB (21°CDB) / 60°FWB (15.6°CWB) (Indoor temperature), 47°FDB
(8.3°CDB) / 43°FWB (6°CWB) (Outdoor temperature).
2. The total ability of connected indoor units is up to 18.0 kBtu/h.
3. It is impossible to connect only one indoor unit.
4. Wall type of indoor unit: CTXS-L, FTXS-L series
Duct type of indoor unit: CDXS-L, FDXS-L series
3D058841B
3D066341
Combination
of
indoor unit
Type of indoor unit
Capacity of each indoor unit
Each capacity (kBtu/h) Total capacity (kBtu/h) Total input (W) Total current (A)
Power
factor (%)
A room B room A room B room Rating (min ~ max) Rating (min ~ max) Rating (min ~ max) Rating
07 Wall 7.00 7.00 5.50 ~ 7.60 500 330 ~ 560 2.3 1.5 ~ 2.5 96
09 Wall 9.00 9.00 5.50 ~ 9.30 750 330 ~ 780 3.4 1.5 ~ 3.5 96
09 Duct 8.00 8.00 5.00 ~ 8.00 830 390 ~ 830 3.8 1.8 ~ 3.8 96
07+07 Wall Wall 7.00 7.00 14.00 6.70 ~ 15.00 920 350 ~ 1020 4.0 1.5 ~ 4.5 99
07+09 Wall Wall 7.00 9.00 16.00 6.70 ~ 17.00 1150 350 ~ 1280 5.1 1.5 ~ 5.6 99
07+09 Wall Duct 6.56 8.44 15.00 6.40 ~ 15.50 1260 420 ~ 1330 5.5 1.8 ~ 5.8 99
09+09 Wall Wall 9.00 9.00 18.00 6.70 ~ 19.00 1420 350 ~ 1700 6.2 1.5 ~ 7.5 99
09+09 Wall Duct 8.50 8.50 17.00 6.40 ~ 17.50 1600 420 ~ 1750 7.0 1.8 ~ 7.7 99
09+09 Duct Duct 8.00 8.00 16.00 6.10 ~ 16.10 1760 490 ~ 1800 7.7 2.2 ~ 7.9 99
Combination
of
indoor unit
Type of indoor unit
Capacity of each indoor unit
Each capacity (kBtu/h) Total capacity (kBtu/h) Total input (W) Total current (A)
Power
factor (%)
A room B room A room B room Rating (min ~ max) Rating (min ~ max) Rating (min ~ max) Rating
07 Wall 8.60 8.60 5.90 ~ 9.20 660 440 ~ 710 2.9 2.0 ~ 3.1 98
09 Wall 11.00 11.00 5.90 ~ 11.80 910 440 ~ 980 4.0 2.0 ~ 4.3 98
09 Duct 11.00 11.00 5.60 ~ 11.50 980 490 ~ 1050 4.3 2.2 ~ 4.7 98
07+07 Wall Wall 8.60 8.60 17.20 8.20 ~ 18.80 1290 530 ~ 1430 5.7 2.3 ~ 6.3 99
07+09 Wall Wall 8.58 11.02 19.60 8.20 ~ 21.40 1550 530 ~ 1710 6.8 2.3 ~ 7.5 99
07+09 Wall Duct 8.58 11.02 19.60 8.10 ~ 21.00 1670 580 ~ 1890 7.3 2.5 ~ 8.3 99
09+09 Wall Wall 11.00 11.00 22.00 8.20 ~ 24.00 1880 530 ~ 1970 8.3 2.3 ~ 8.7 99
09+09 Wall Duct 11.00 11.00 22.00 8.10 ~ 23.60 2080 580 ~ 2130 9.1 2.5 ~ 9.4 99
09+09 Duct Duct 11.00 11.00 22.00 8.00 ~ 23.20 2190 640 ~ 2290 9.6 2.8 ~ 10.1 99

Table of Contents

Other manuals for Daikin SUPER MULTI NX FDXS09LVJU

Related product manuals