Service
Manual
SiBE121021_C
E-Series / F-Series / G-Series
[Applied Models]
Inverter Multi : Cooling Only
Inverter Multi : Heat Pump

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi NX FHQ50BVV1B and is the answer not in the manual?

Daikin Super Multi NX FHQ50BVV1B Specifications

General IconGeneral
ModelFHQ50BVV1B
SeriesSuper Multi NX
CategoryAir Conditioner
Cooling Capacity5.0 kW
Heating Capacity5.8 kW
RefrigerantR32
Power Source220-240V, 50Hz

Summary

Service Manual

Introduction

Safety Cautions

Important warnings and cautions for safe repair work, classified into Warning and Caution categories.

Part 2 Specifications

Part 3 Printed Circuit Board Connector Wiring Diagram

Indoor Unit

Details connectors and parts for Indoor Units, including Control PCB, Signal Receiver/Display PCB, and INTELLIGENT EYE Sensor PCB.

Part 4 Function and Control

Function of Indoor Unit (RA Models)

Explains functions like Temperature Control, Frequency Principle, Operation Starting Control, Airflow Direction Control, and Fan Speed Control.

Function of Indoor Unit (SA Models)

Details functions such as Drain Pump Control, Thermostat Sensor in Remote Controller, Freeze Prevention Control, and Hot Start Control.

Control Specification

Details control specifications like Mode Hierarchy, Frequency Control, Controls at Mode Changing/Start-up, and various protection functions.

Part 5 Operation Manual

Part 6 Service Diagnosis

Troubleshooting with LED

Guides on troubleshooting indoor and outdoor unit abnormalities indicated by LED blinking patterns.

Problem Symptoms and Measures

Lists common problems, check items, details of measures, and reference pages for diagnosis.

Service Check Function

Provides step-by-step procedures for service check functions using remote controller codes and diagnosis methods.

Code Indication on Remote Controller

Lists error codes for RA and SA Indoor Units, along with their descriptions and reference pages for troubleshooting.

Troubleshooting for RA Indoor Unit

Addresses specific issues like PCB abnormalities, freeze-up/peak-cut control, fan motor issues, thermistor errors, and signal transmission.

Troubleshooting for SA Indoor Unit

Covers issues like Indoor Unit PCB Abnormality, Drain System Abnormality, Fan Motor issues, Thermistor Abnormality, and Signal Transmission Errors.

Troubleshooting for Outdoor Unit

Details troubleshooting steps for Outdoor Unit issues like Anti-icing, PCB Abnormality, Compressor Overload, DC Fan Lock, Input Overcurrent, and Refrigerant Shortage.

Part 7 Removal Procedure

Part 8 Trial Operation and Field Settings