Indoor Units EDUS121131
268 Installation Manual
INSTALLING THE DUCT
Outlet side
Connect the duct according to the inside of the outlet-side flange.
Wrap the outlet-side flange and the duct connection area with aluminum tape or something similar to prevent air escaping.
Caution
Be sure to insulate the duct to prevent condensation from forming. (Material: glass wool or polyethylene foam, 1in thick)
Use electric insulation between the duct and the wall when using metal ducts to pass metal laths of the net or fence shape or
metal plating into wooden buildings.
WIRING
See the installation manual supplied with the outdoor unit.
HOW TO CONNECT WIRINGS.
Wire only after removing the control box lid as shown in the Fig.
Wrap the remote controller wiring with the sealing material
as shown in the figure below.
(Otherwise, moisture or small creatures such as insects from
the outside may cause short-circuit inside the control box.)
Attach securely so that there are no gaps.
Inside
unit
Outside
unit
[How to adhere it]
Wire
(accessory)
Sealing material
Wiring
through hole
Remote controller wiring
Control box lid
Wiring Diagram
(Rear)
Conduit mounting plate
(accessory)
Conduit
(field supply)
Lock nut
(field supply)
Screw
(accessory)
Power supply wiring
Ground wire