SiBE121021_C Piping Diagrams
Appendix 473
4MXS68F2V1B
4MXS80E2V3B, 4AMX80E2V3B
12.7CuT
9.5CuT
12.7CuT
6.4CuT
12.7CuT
12.7CuT
12.7CuT
12.7CuT
12.7CuT
12.7CuT
6.4CuT
12.7CuT
6.4CuT
6.4CuT
7.9CuT
OUTDOOR TEMPERATURE
THERMISTOR(DOA)
HEAT EXCHANGER
THERMISTOR(DE)
REVERSING
SOLENOID
VALVE
DISCHARGE PIPE
THERMISTOR(DO)
GAS LINE
STOP VALVE
LIQUID LINE
STOP VALVE
LIQUID PIPE
THERMISTOR(DLA)
LIQUID PIPE
THERMISTOR(DLB)
LIQUID PIPE
THERMISTOR(DLC)
LIQUID PIPE
THERMISTOR(DLD)
FIELD
PIPING
LIQUID
FIELD
PIPING
GAS
ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
ROOM C
(6.4 CuT)
ROOM D
(6.4 CuT)
ROOM A
(9.5 CuT)
ROOM B
(9.5 CuT)
ROOM C
(12.7 CuT)
ROOM D
(12.7 CuT)
HEADER
HEAT EXCHANGER
DC FAN MOTOR
PROPELLER FAN
M
MUFFLER
REFRIGERANT FLOW
COOLING
HEATING
COMPRESSOR
ACCUMULATOR
CAPILLARY TUBE
DISTRIBUTOR
HEADER
FILTER
HEADER
ACCUMULATOR
GAS PIPE THERMISTOR(DGD)
GAS PIPE THERMISTOR(DGC)
GAS PIPE THERMISTOR(DGB)
GAS PIPE THERMISTOR(DGA)
MOTOR OPERATED VALVE
MOTOR OPERATED VALVE
MOTOR OPERATED VALVE
MOTOR OPERATED VALVE
EVA
EVB
EVC
EVD
FILTER
FILTER
FILTER
FILTER
3D055041
OUTDOOR UNIT
12.7CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
15.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
15.9CuT
15.9CuT
9.5CuT
15.9CuT
9.5CuT
15.9CuT
9.5CuT
9.5CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
12.7CuT
12.7CuT
12.7CuT
12.7CuT
15.9CuT 12.7CuT
15.9CuT
OUTDOOR UNIT
HEADER
HEAT EXCHANGER
OUTDOOR
TEMPERATURE
THERMISTOR
HEAT EXCHANGER
(CONDENSER)
THERMISTOR
CAPILLARY TUBE
DISTRIBUTOR
4-WAY
VALVE
DC FAN MOTOR
PROPELLER FAN
M
DISCHARGE PIPE
THERMISTOR
MUFFLER
REFRIGERANT FLOW
COOLING
HEATING
COMPRESSOR
ACCUMULATOR ACCUMULATOR
GAS LINE
STOP VALVE
MUFFLER
MUFFLER
HEADER
FILTER
LIQUID LINE
STOP VALVE
HEADER
RECEIVER
MOTOR OPERATED
VALVE (A)
MOTOR OPERATED
VALVE (B)
MOTOR OPERATED
VALVE (C)
MOTOR OPERATED
VALVE (D)
EVA
EVB
EVC
EVD
LIQUID PIPE
THERMISTOR
(ROOM-A)
LIQUID PIPE
THERMISTOR
(ROOM-B)
LIQUID PIPE
THERMISTOR
(ROOM-C)
LIQUID PIPE
THERMISTOR
(ROOM-D)
FILTER
FILTER
FILTER
FILTER
GAS PIPE THERMISTOR
(ROOM-A)
GAS PIPE THERMISTOR
(ROOM-B)
GAS PIPE THERMISTOR
(ROOM-C)
GAS PIPE THERMISTOR
(ROOM-D)
ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
ROOM C
(6.4 CuT)
ROOM D
(6.4 CuT)
FIELD
PIPING
LIQUID
ROOM A
(9.5 CuT)
ROOM B
(12.7 CuT)
ROOM C
(15.9 CuT)
ROOM D
(15.9 CuT)
FIELD
PIPING
GAS
C: 3D051937D

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi NX FHQ50BVV1B and is the answer not in the manual?

Daikin Super Multi NX FHQ50BVV1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi NX FHQ50BVV1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals