PIM00413
Hybrid Hydraulic System
Super Unit
SUT00S3016-30 SUT06S3016-30
SUT00S6007-30 SUT06S6007-30
SUT00D4016-30 SUT06D4016-30
SUT00D6021-30 SUT06D6021-30
SUT10D6021-30
Operation Manual
【Originally】
DAIKIN INDUSTRIES, LTD.
Oil Hydraulics Division

Table of Contents

Questions and Answers

  • V
    veatonAug 18, 2025
    What to do if my Daikin SUT10D6021-30 shows error E14?
    • A
      anthony37Aug 19, 2025
      If your Daikin Portable Generator displays error code E14, it could be due to the power supply voltage being out of the specified range or the braking force being too large during deceleration. Check the power supply voltage in monitor mode and ensure it is within the required range. If the braking force is too large, reduce the parameter value of deceleration time setting or reduce the value of load command rate at the time of regeneration and regenerative load ratio command at the time of deceleration.
  • K
    Kathryn WrightAug 21, 2025
    What to do if my Daikin SUT10D6021-30 Portable Generator displays error E16?
    • J
      Jasmine GlennAug 21, 2025
      If your Daikin Portable Generator shows error E16, it could be due to high power supply voltage, a controller failure, or rapid deceleration in PQ selection switching. You should check the power supply voltage in monitor mode and ensure it is within the required range. If the voltage is normal, the controller may need to be replaced. If rapid deceleration is the issue, reduce the parameter value of deceleration time setting or reduce the value of load command rate at the time of regeneration, and regenerative load ratio command at the time of deceleration.
  • D
    Dawn JohnsonAug 23, 2025
    What does error code E15 mean on my Daikin Portable Generator?
    • D
      denise85Aug 23, 2025
      Error code E15 on your Daikin Portable Generator can indicate a low power supply voltage, re-turning on the power before the display has completely disappeared, or a controller failure. Check the power supply voltage in monitor mode and ensure it is within the required range. Also, ensure you re-power the device only after the display has completely disappeared. If these steps don't resolve the issue, the controller may need to be replaced.
  • K
    Karen BennettAug 26, 2025
    What does error code E17 mean on my Daikin SUT10D6021-30 Portable Generator?
    • S
      Sarah FullerAug 26, 2025
      If your Daikin Portable Generator is showing error code E17, this could be due to a large load torque, defects in motor control due to the effect of noise. You may need to replace the motor pump, the controller, or add a noise filter.
  • J
    John DavisAug 27, 2025
    What to do if my Daikin SUT10D6021-30 shows error E13?
    • T
      Tony KingAug 28, 2025
      If your Daikin Portable Generator displays error code E13, it could be due to a short circuit of the regenerative resistor, the resistance value of the regenerative resistor being too small, or the motor regenerative energy being too large. Replace the regenerative resistor. Check the resistance value of the regenerative resistor. Increase the acceleration/deceleration time and lighten the load.
  • C
    Charles HolmesAug 30, 2025
    Why does my Daikin Portable Generator show error E09?
    • F
      Felicia MillerAug 30, 2025
      Daikin Portable Generator error E09 can be caused by several issues: a layer short of the motor coil, a short circuit of the motor, damage to the controller, a disconnected encoder connector, damage to the encoder harness, or failure of the encoder. To resolve this, you might need to replace the motor pump or the controller, connect the encoder connector, or replace the encoder harness.
  • R
    raymond63Sep 1, 2025
    Why does my Daikin Portable Generator show error E10?
    • T
      thompsondannySep 1, 2025
      Daikin Portable Generator error E10 can occur due to a layer short of the motor coil, a short circuit of the motor, damage to the controller, a disconnected encoder connector, damage to the encoder harness, or failure of the encoder. The suggested solutions are to replace the motor pump or the controller, connect the encoder connector, or replace the encoder harness.
  • D
    Danny CollinsSep 3, 2025
    What to do if my Daikin SUT10D6021-30 Portable Generator displays error E12?
    • M
      Matthew WongSep 3, 2025
      If your Daikin Portable Generator is showing error E12, it could indicate a failure of the encoder, failure of the controller, or noise interference. Consider replacing the motor pump or the controller. You can also try adding a noise filter.
  • K
    kevin94Sep 6, 2025
    What causes error E21 on a Daikin SUT10D6021-30 Portable Generator?
    • F
      fernandezlauraSep 6, 2025
      Error E21 on a Daikin Portable Generator can be caused by a disconnection of the motor wiring or failure of the output device. To fix this, replace the motor cable or the controller.
  • M
    Melinda RamseySep 8, 2025
    What does error E11 mean on my Daikin SUT10D6021-30 Portable Generator?
    • R
      Ryan ShieldsSep 8, 2025
      Error E11 on your Daikin Portable Generator indicates that the encoder connector is disconnected or the encoder harness is damaged. Connect the encoder connector or replace the encoder harness to resolve this issue.

Summary

Safety Precautions

General Precautions

Key safety guidelines for handling, operation, and maintenance.

Precautions for Use

Specific advice on operating the hydraulic unit safely.

Safe Operation Practices

Guidelines for safe installation, wiring, operation, maintenance, and disposal.

Specifications and Operating Conditions

Start-up Procedure

Arrival Product Confirmation

Transportation and Installation

Piping Procedures

SUT00 Porting Specifications

Details on port types, sizes, and pressure for SUT00 motor pump models.

SUT06;SUT10 Porting Specifications

Details on port types, sizes, and pressure for SUT06/SUT10 unit models.

Electric Wiring Instructions

Test Run Procedures

Initial Test Run Steps

Steps for performing the initial test run after installation and wiring.

Panel Operation Guide

Parameter Adjustment

Parameter List

A comprehensive list of adjustable parameters with their settings and descriptions.

Control Signal Configuration

Settings for start-stop signals, PQ selection, and output signals.

Performance Setting Parameters

Parameters for adjusting pressure, flow rate, and operational characteristics.

Safety and Function Parameters

Configuration for pressure switch and other operational functions.

Troubleshooting Guide

Fault Diagnosis

Information on protection signals, alarms, and warnings for diagnosing faults.

Periodic Inspection

Schedule and methods for routine maintenance checks.

Output Signal Timing Charts

Daikin SUT10D6021-30 Specifications