Instructions Manual
Dryair DK
REFRIGERATED TYPE COMPRESSED AIR DRYERS
Dryair DK10 - Dryair DK260
Rev No:4

Questions and Answers

  • B
    Brett HernandezAug 7, 2025
    What to do if DALGAKIRAN Dryair DK30 Dehumidifier's indicator light is on but the refrigerant compressor does not turn on?
    • E
      Eric RichardsonAug 7, 2025
      If the DALGAKIRAN Dehumidifier's indicator light is on, but the refrigerant compressor isn't running, it could be due to several reasons. First, the electrical phases might be inverted; try inverting two of the phases. Second, the refrigeration unit might not be functioning, so check the refrigeration compressor. Third, the refrigerant high pressure protection may have tripped; manually reset the high pressure switch. Finally, the ambient temperature might be too high; ensure the dryer is operating within its designed temperature conditions, as detailed in this manual.

Summary

Important Safety Notes

1.1. Transportation

Safe handling and movement procedures for the dryer.

1.2. Positioning

Guidelines for optimal placement and ventilation of the dryer.

1.3. Installation

Instructions for authorized personnel on proper dryer installation.

1.4. Before Operating

Pre-operation checks and precautions for safe use.

1.5. Maintenance by an Engineer

Procedures for qualified personnel performing maintenance.

1.6. Maintenance by the user

Routine tasks for users to keep the dryer clean and functional.

Introduction to the Dryer

Working details

Describes the refrigerant and compressed air circuits' operation.

Operation

3.1. Control Panel Overview

Identifies and explains the elements on the dryer's control panels.

3.2. During Operation

Covers daily startup, shutdown, and ongoing monitoring procedures.

Technical Specifications

Diagrams

Components Location

Troubleshooting

DALGAKIRAN Dryair DK30 Specifications

General IconGeneral
Operating Temperature Range5°C to 35°C
RefrigerantR410A
Dehumidification Capacity30 L/day
Water Tank Capacity5.5 l
Noise Level48 dB(A)
TypeRefrigerant