PROBLEM POSSIBLE CAUSE
The unit does not operate • Not plugged in
• The circuit breaker tripped or blown fuse
Turns on and off
frequently
• The room temperature is hotter than normal
• The door is open too often
• The door is not closed completely
• The temperature control is not set correctly
• The door gasket does not seal properly
• The unit does not have proper clearance
Vibrations • Check that the keg cooler is level
The keg cooler seems to
make too much noise
• The rattling noise may come from the fl ow of refrigerant, which is
normal
• Gurgling, caused by liquid refrigerant cycling is normal
• Contraction and expansion of the inside walls may cause popping
and crackling noises
• The keg cooler is not level
The door will not close
properly
• The keg cooler is not level
• The door was reversed and not properly reinstalled
• The gasket is dirty
• The shelves or stand are out of position
• The keg is not properly centered in the unit
• The casters are not attached
Excessive beer foam • Ensure the beer line hose from the tower and the CO
2
air line hose
from the CO
2
regulator are attached to the correct connections on
the coupler; beer line to the top of the coupler, CO
2
air line to the
side of the coupler
• Check that there are no leaks in any connections
• Ensure that the reed valve in the CO
2
connection at the coupler
has a hole in it
• The CO
2
pressure may be set too high; try turning the pressure
down
• Ensure that the valve spool plastic rod is inserted into the coupler
Weak beer fl ow • Ensure the beer line hose from the tower and the CO
2
air line hose
from the CO
2
regulator are attached to the correct connections on
the coupler; beer line to the top of the coupler, CO
2
air line to the
side of the coupler
• Check that there are no leaks in any connections
• Ensure that the reed valve in the CO
2
connection at the coupler
has a hole in it
• The CO
2
pressure may be set too low; try turning the pressure up
• Ensure there are no bends or kinks in any of the hoses that could
impede fl ow