EasyManuals Logo
Home>Danfoss>Heat Pump>Bluestar Series

Danfoss Bluestar Series User Manual

Danfoss Bluestar Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
8510198 P03-A © Danfoss Commercial Compressors 03/05
Danfoss Commercial
Compressors
INSTRUCTIONS
Bluestar & Optyma
50 Hz L P H 60 Hz
MGM/MGZ 016-018-022-028 700 500 392 MGM/MGZ 018-022
HGM/HGZ 018 HGM/HGZ 018
LGZ 022 LGZ022
MGM/MGZ 032-036-040 800 600 442 MGM/MGZ 028-032-036-040
HGM/HGZ 022-028-032 - HGM036 HGM/HGZ 022-028
LGZ 028-040 LGZ028
MGM/MGZ 050-064-080 1000 700 555 MGM/MGZ 050-064
HGM/HGZ 040-050 -HGZ 036 HGM/HGZ 032-036-040-050
LGZ 044-050 LGZ044-050
MGM/MGZ 100-125-144-160 1200 800 671 MGM/MGZ 080-100-125-144-160
HGM/HGZ 064-080-100 HGM/HGZ 064-080-100
LGZ 088-100 LGZ088-100
HGM/HGZ 125-144-160 1500 870 975 HGM/HGZ 125-144-160
50 Hz
Comp-
LPH
resseur
MCZC030 MTZ18
500 620 451
MCZC038 MTZ22
MCZC048 MTZ28
MCZC054 MTZ32
630 650 605
MCZC060 MTZ36
MCZC068 MTZ40
MCZC086 MTZ51
MCZC096 MTZ57 755 700 656
MCZC108 MTZ65
MCZC121 MTZ73
MCZC136 MTZ81 900 900 759
MCZC171 MTZ100
MGZC215 MTZ125
MGZC242 MTZ144 1350 820 759
MGZC271 MTZ160
50 Hz
Comp-
LPH
resseur
LCHC048 NTZ048 500 620 451
LCHC068 NTZ068
LCHC096 NTZ096 630 650 605
LCHC108 NTZ108
LCHC136 NTZ136 755 700 656
LCHC215 NTZ215
900 900 759
LCHC271 NTZ271
LGHC048 NTZ048 700 500 392
LGHC068 NTZ068
LGHC096 NTZ096 800 600 442
LGHC108 NTZ108
LGHC136 NTZ136 1000 700 555
LGHC215 NTZ215
1200 800 671
LGHC271 NTZ271
L
P
H
L
P
H
CONDENSING UNITS
-25 -15 -5 5 10
50
45
35
25
15
HGM R22
-30 -20 -10 0 5
50
45
35
25
15
MGZ R404A - R507A
-15
-5
510
50
45
35
25
15
MGZ R134a
Plage d'application MBP
28
32
38
43
46
T° amb (°C)
T° evap (°C)
R404A/R507A
-30 -25 -20 -15 -10 -5 0 5 10
Plage d'application LBP
27
32
38
43
46
-45 -40 -35 -30 -25 -20 -15 -10
T° amb (°C)
T° evap (°C)
R404A/R507A
-15
-35
25 -30
50
45
35
25
15
LGZ R404A - R507A
50
45
35
25
-25 -15 -5 5 10
15
MGM R22
-30 -20 -10 0
10
50
45
35
25
15
HGZ R404A - R507A
-15
-5
51520
50
45
35
25
15
HGZ R134a
Temperature évaporée (C°)
Temperature ambiante (C°)
SH = 10K
Surchauffe limitée
SH = 10K
Application MBP Application LBP
SH = 10 K
RGT = 20 °C
Fig. 1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Bluestar Series and is the answer not in the manual?

Danfoss Bluestar Series Specifications

General IconGeneral
BrandDanfoss
ModelBluestar Series
CategoryHeat Pump
LanguageEnglish

Related product manuals