4.1 DWH
DHP-L with DWH 300 DHP-L with DWH 200
455
596
610
80
1845 (±10)
4
5
3
7 8
9
10
11
5
690
110
528
300
440
1
2
6
1538 (±10)
40±10
6
1538 (±10)
455
596
690
40±10
110
528
610
80
300
440
1
2
6
4
5
3
7 8
9
10
11
5
6
1 Brine in, 28 Cu
2 Brine out, 28 Cu
3 Heating system supply pipe, 22 Cu: 4-10 kW, 28 Cu: 12-16 kW
4 Heating system return pipe, 22 Cu: 4-10 kW, 28 Cu: 12-16 kW
5 Lead-in for supply, sensor and communication cables
6 Return line from water heater to heat pump Ø 22 mm
7 Hot water Ø 22 mm
8 Cold water Ø 22 mm
9 Supply line from heat pump (diam) 22 mm
10 Connection for bleed valve, 22 Cu
11 Combined temperature and pressure relief valve
The brine pipes can be connected on either the left or right-hand sides of the heat pump.