OCTOBER 2022
DANIEL
®
LIQUID TURBINE METER
USER MANUAL
SERIES 1500 LIQUID TURBINE METER
NPS 3 THROUGH 24
Decades Proven. Field Chosen.

Table of Contents

Questions and Answers

  • M
    michelekingJul 30, 2025
    What to do if there are no output pulses from the DANIEL 1500 Measuring Instruments amplifier module?
    • B
      Brenda HughesJul 30, 2025
      If there are no output pulses from the amplifier module, several factors could be at play. First, ensure the input voltage to the amplifier is within the required range of 10-30 VDC. If the voltage is correct, the pickoff might be damaged or shorted; its resistance across the leads should be between 600-900 Ohms, consider replacing it. A damaged amplifier module could also be the culprit, in which case, replace it. Finally, troubleshoot the internal assembly to ensure the meter rotor is turning.
  • K
    katherinejacksonAug 8, 2025
    Why is the readout inaccurate on my DANIEL Measuring Instruments?
    • V
      Veronica OwenAug 8, 2025
      An inaccurate readout on your DANIEL Measuring Instruments could stem from a few potential issues. Check the rotor blades for any foreign material and clean them if necessary. If the rotor blades are bent, consider returning the instrument to the factory for replacement or repair. Also, troubleshoot any defective accessory equipment.
  • C
    courtney57Aug 18, 2025
    How to fix a turbine meter rotor that is not turning in DANIEL Measuring Instruments?
    • J
      jcampbellAug 18, 2025
      If the turbine meter rotor isn't turning, it could be due to a defective rotor bearing or the rotor being damaged by foreign material. In either case, return the rotor assembly to the factory for replacement or repair.

Summary

Part I Plan

Introduction to the Series 1500 LTM

Overview of the manual's purpose, document structure, and the Series 1500 LTM.

Operating Conditions and Specifications

Details fluid phase, temperature, pressure, flow rate, and environmental limits for the meter.

Part II Installation

Installation Prerequisites

Covers pre-installation checks, torque specifications, and required tools.

Installation Procedures

Step-by-step guide for cathodic protection, mechanical assembly, and fasteners.

Part III Operation

Operation Parameters and Normal Operation

Explains operation overview, normal usage, and back pressure calculation for accurate measurement.

Part IV Maintenance

Planned Maintenance

Covers maintenance considerations, tools required, and planned tasks like inspection and cleaning.

Corrective Maintenance and Troubleshooting

Provides guidance on troubleshooting common issues and verifying meter operation post-maintenance.

Spare Parts

Identifies recommended spare parts for LME assembly and the process for ordering them.

Decommissioning the Turbine Meter

Procedures for safely shutting down, disassembling, and preparing the meter for shipment.

DANIEL 1500 Series Specifications