GSM Gate Opener Introduction

Safety Directions

Operational Safety Guidelines

Covers safe startup, interference, gas stations, blasting areas, and general device usage.

Standard Packing List

Physical Layout and Interface

Control Unit Layout and Indicators

Details the physical layout of the RTU5024 control unit, its LEDs, and connection terminals.

Product Features

Key Functionalities Overview

Highlights no call charges, remote operation, security, user management, and relay output capabilities.

SMS Command Configuration

Initial Setup and Password Management

Covers initial notes, changing passwords, and secure programming via SMS commands.

Authorized User Management

Adding, inquiring about, and removing authorized phone numbers via SMS commands.

Access Control and Relay Settings

Configuring access modes, relay close time, and checking system status using SMS.

System Status and Manual Control

Checking GSM signal, confirmation settings, and controlling the relay via SMS commands.

Installation Guide

Connecting Electrical Equipment

Instructions for wiring the control unit to electronic locks or other electrical equipment.

Mainframe Mounting Instructions

Guidance on securely mounting the control unit for optimal performance and access.

Technical Specifications

Important Information

Maintenance and Troubleshooting

Product Warranty Information

Overview

The RTU5024 is a GSM Gate Opener and Remote Switch designed for authorized door access, gate control, remote equipment switching, and car parking systems. It allows users to turn ON/OFF systems, machines, and equipment remotely with a FREE call from their mobile phone, providing a secure and convenient way to manage access and control.

Function Description:

The RTU5024 operates by rejecting calls from authorized numbers and then carrying out a pre-programmed ON/OFF action. This means there are no call charges for the user. It can be used to open sliding gates, swing gates, garage doors, barriers, shutters, and other access doors or machines. The device uses caller ID for identification, ignoring calls from unknown numbers to enhance security. It can be operated from anywhere without distance limitations, as long as there is GSM network coverage. The unit features one output with a relay rated at 3A/240VAC for connecting to the switch of a door or machine. The relay action can be configured to return an SMS confirmation to the owner, a feature that is editable by the user. The device supports up to 200 authorized phone numbers, eliminating the need for multiple remote controls for different users.

Important Technical Specifications:

  • Rated Voltage: 12VDC 1A
  • Working Temperature: -10°C ~ +60°C
  • Storage Temperature: -20°C ~ +60°C
  • Relative Humidity: 10-90%, No condensation
  • Work Frequency: 900/1800MHz
  • Communication Protocol: GSM PHASE 2/2+ (including data service)
  • Related Voltage of the Output Relay: 3A/240V AC
  • Net Weight: 0.30Kg

Usage Features:

  • Free Operation: No call charges as the device rejects calls from authorized numbers and performs the ON/OFF action on the first ring.
  • Multiple Applications: Suitable for gates, bollards, barriers, garage doors, shutters, and various access doors or machines.
  • Secure Access: Uses caller ID for identification, ignoring unknown callers.
  • Remote Control: Can be operated from anywhere with GSM network coverage.
  • User Management: Add or remove users easily via SMS text commands.
  • Capacity: Supports up to 200 authorized phone numbers.
  • Relay Output: One output with a 3A/240VAC relay for connecting to a door or machine switch.
  • SMS Confirmation: Optional SMS confirmation to the owner after a relay action.
  • Programmable Relay Close Time: The relay close time can be set from 0 to 9.5 seconds. A setting of '00' keeps the relay closed until the next call, useful for remote switching of electrical appliances for extended periods.
  • GSM Signal Quality Check: Users can check the GSM signal quality via SMS command (pwd#CSQ?) to ensure optimal performance. A signal level above 12 is recommended for reliable operation.
  • SMS Control: The relay can be controlled ON/OFF directly via SMS commands (pwd# ON # and pwd# OFF #).
  • Password Protection: The device is protected by a password (default is 1234), which can be changed by the user. All settings are configured via SMS commands using this password.
  • Authorized Number Management: Users can set up, inquire about, and remove authorized numbers via SMS commands.
  • Access Control Options: Configure whether all calling numbers can access the device (pwd#AA#) or only authorized numbers (pwd#AU#, default and recommended).

Maintenance Features:

  • Qualified Maintenance Service: Maintenance should only be carried out by qualified personnel.
  • Troubleshooting SMS Issues: If the remote control works but the unit fails to send SMS texts, users should power cycle the Control Unit, wait one minute, and retest. They should also check settings and GSM signal strength.
  • SIM Card Check: If the Control Unit operates but cannot send SMS texts, changing the SIM Card is recommended for troubleshooting.
  • Factory Reset: The RTU5024 can be reset to factory defaults by sending the SMS command pwd#RESET# or by pressing the RESET key beside the SIM Card for several seconds until the RUN LED stays ON.
  • Installation Guidelines: The mainframe should be installed in a secure location inaccessible to unauthorized persons, with a stable power source and sufficient GSM signal coverage.
  • Important Information: Users are advised to read the manual carefully, install the system in a hidden place, avoid water exposure, and ensure a secure connection to the main power supply.

Safety Directions:

  • Safe Startup: Do not use the device where GSM equipment is prohibited or might cause disturbance or danger.
  • Interference: All wireless equipment may interfere with network signals and affect performance.
  • Avoid Use at Gas Stations: Power off the device near fuels or chemicals.
  • Blasting Places: Follow restrictive regulations and avoid using the device in blasting areas.
  • Reasonable Use: Install the product in suitable places as described in the documentation, avoiding signal shielding.

DANIU RTU5024 Specifications

General IconGeneral
BrandDANIU
ModelRTU5024
CategoryGate Opener
LanguageEnglish