TABLE NO. 1
NFPA 1901 TEST
TEST Recom- Min. Min. Min. Net Disch. Suction
No. GPM mended Nozzle Disch. Pump Lines Hose
Nozzles Press. PSI Press. PSI Press. PSI
1 2500 (2), 2-1/4” 69 144 150
(2 Groups)
(3), 100’
2 1750 (2), 2” 55 195 200 Siamesed
3 1250 (2), 1-1/2” 88 246 250
4 2500 (2), 2-1/4” 69 159 165
1 3000 (2), 2-1/2” 65 146 150
(2 Groups)
(3), 100’
2 2100 (2), 2” 78 196 200 Siamesed
3 1500 (2), 1-3/4” 68 247 250
4 3000 (2), 2-1/2” 65 161 165
1 3000 (2), 2-1/2” 65 96 100
(2 Groups)
(3), 100’
2 2100
(2), 2”
78 146 150
Siamesed
3 1500
(2), 1-3/4”
68 197 200
1 3500
45 95 100
(2 Groups)
(3), 100’
(1), 2-1/4” 44 Siamesed
2 2450 (2), 2-1/4” 67 146 150 &
3 1750 (2), 2” 55 197 200
(2)-50’
Siamesed
Class A
Min. discharge pressures listed above are for pumps operating with full 10’ static suction lift. These
pressures must be increased by 1 PSI for each 2.3 ft. less than 10’ of lift.
(2) 20’ of 8”
2500 GPM Fire Pump
20’ of 8”
3000 GPM Fire Pump
(2) 20’ of 8”
3500 GPM Industrial Fire Pump
3000 GPM Industrial Fire Pump
(2) 20’ of 8”
IF FURTHER INFORMATION IS NEEDED, CALL W.S. DARLEY & CO. AT
CHIPPEWA FALLS, WI. AT 800-634-7812 or 715-726-2650
Prepared by: CJC
Approved by: WAH
Revised by: CWY
4
Rev. #: 4
Date: 7/8/13
1201500