72-1002
Model
5740
COUNTER
reference
schematic,
includes
7
one-digit
display
units,
four
anode-driver
circuits
that
are
gated
with
the
digit
select
con
trol
signal
of
the
multiplexer,
two
BCD-
to-seven
segment
converters
for
the
groups
of
digit
data
transmitted
from
the
main
assembly,
resistor-coupled
ground
signal
for
the
selected
decimal
point,
and
tran
sistor
drivers
for
the
OVERFLOW
and
GATE
annunciators.
Note
that
the
decimal
points
of
the
two
more
significant
digits
(not
used
as
decimal
points)
are
used
as
the
annunciators
in
the
upper
left
(in
stead
of
lower
right)
location.
This
in
verted
position
of
the
display
is
com
pensated
for
by
suitable
selection
of
the
seven
segments
to
display
the
desired
digit.
3.12
BCD
OPTION
When
BCD
option
is
installed,
the
mea
sured
value
in
the
latching
registers
are
connected
to
the
PC
board
edge
terminals.
In
addition,
certain
status
and
control
signals
are
also
connected
to
the
PC
board
to
provide
user
capability
for
interpret
ing
the
values
and
for
printing
only
when
the
value
has
been
latched
between
mea
surements
.
As
shown
in
Drawing
75-1005
and
the
main
reference
schematic,
the
BCD
values
for
the
three
less
signifleant_digits
are
available
at
their
respective
latches
and
are
connected
directly
to
the
output
ter
minals.
The
four
more
significant
digits
are
de—multiplexed
and
transferred
to
independent
latches
Z201
to
220*+
in
the
BCD
option
components,
from
which
they
are
connected
to
the
edge
terminals.
Decimal
point
indicator
signals
are
developed
by
the
rotary
switch
action,
and
a
ground
level
at
any
position
se
lects
that
point.
Ungrounded
levels
are
held
at
+5V.
A
Print-Enable
status
signal
is
de
veloped
by
gating
the
instrument
Hold
and
Transfer
signals.
The
Print
Enable
is
a
low
level
when
either
the
Transfer
control
is
OFF,
or
when
the
Hold
signal
is
ON.
Thus,
the
user
may
recognize
when
the
BCD
data
is
static
during
the
Automatic
measuring
modes,
or
during
the
manual
measuring
modes,
respective
ly.
312
COPVBIOHT
U76
DATA
PRECISION
CORPORATION
PRINTED
IN
THE