Extended System-Level Command Functions
46 Class Series 2 Programmer’s Manual
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Menu Item (or Number)
(if available)
Command
Equivalent
Comm TOF Commands
CT
Y, N
Y = Enabled,
N = Disabled
Communications N/A
Continuous Label Length
CL
0 – 9999 1/100 in. Media Settings (12)
<STX>c
Control Codes
CC
S, 1, 2
S = Standard,
1 = Alternate,
2 = Alternate-2
Communications (11)
N/A
Cut Behind
CB
0 – 9 Queued label count Printer Options N/A
Cutter Equipped
CE
A/Y, E, N/D
A, E/Y, N
A or Y = Auto,
E = Enabled,
N or D = Disabled
A = Auto,
E or Y = Enabled,
N = Disabled
Printer Options
<STX>V
(continued)

Table of Contents