EasyManua.ls Logo

Datamax-ONeil A-Class - Page 73

Datamax-ONeil A-Class
334 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 59
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Menu Item (or Number)
(if available)
Command
Equivalent
Sensor Type
ST
G, C, R
G = Gap (edge),
C = Continuous,
R = Reflective
Media Settings (2)
<STX>e,
<STX>r,
<STX>c
Serial Port
SP
xyz See Table 5-12.
Communications
9 & 10
N/A
Single Byte Symbol Set
AS
2-Byte alpha
character
AA – ZZ, printer
resident symbol set
System Settings
<STX>y,
ySxx
Slew Speed
FS
Alpha character
Model specific
ranges; see
Appendix L.
Print Control
<STX>KZSx
Software Switch
SV
Y, N
Y = Processed
N = Ignored
Communications N/A
(continued)

Table of Contents