EasyManuals Logo

Davey CRYSTAL CLEAR User Manual

Davey CRYSTAL CLEAR
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
– 3 –
Weather Protection
Davey Media Filter tanks are made from UV stabilised materials. However to
HQVXUH\HDUVRIUHOLDEOHVHUYLFHLWLVUHFRPPHQGHGWKDWWKH¿OWUDWLRQV\VWHPLV
adequately protected from the weather. For proper care and maintenance of your
¿OWHUVHHVHFWLRQRQ³)LOWHU&DUH´
Assembly
 8QGRWKH9EDQGFODPSRUÀDQJHQXWVDQGUHPRYHWKHPXOWLSRUWYDOYH
 /RRNLQVLGHDQGFKHFNWKHORZHUXQGHUGUDLQDVVHPEO\WRHQVXUHODWHUDOVDUH
secure.
 +DOI¿OOWKHWDQNZLWKZDWHUWRSURYLGHDFXVKLRQIRUWKHPHGLD
4. Make certain the under drain assembly is correctly located onto it’s stand at the
base of the tank.
 3ODFHWKHVDQGJXLGHLQWKHWRSRIWKH¿OWHURSHQLQJ
6. Pour the correct amount of 16/30 or 1mm grade sand or Zelbrite into the tank
UHIHUVSHFL¿FDWLRQVHYHQO\GLVWULEXWLQJLWDURXQGWKHFHQWUDOSLSH/HYHORXWWKH
top of the media bed.
 5HPRYHWKHVDQGJXLGHDQGDOOWUDFHVRIPHGLDIURPWKHWDQNÀDQJH
8. Ensure the closure oring is clean and in the correct position. If necessary, apply a
WKLQ¿OPRIRULQJOXEULFDQWWRWKHRULQJV$VVHPEOHWKHPXOWLSRUWYDOYHWRWKHWDQN
aligning the ports to the appropriate plumbing.
 $SSO\7HÀRQWDSHWRWKHWKUHDGRQWKHSUHVVXUHJDXJHDQGEDUUHOXQLRQVDQG
screw into the multiport valve body. 7 turns of tape is required.
CAUTION
 $QRQUHWXUQYDOYHLVUHTXLUHGLQEHWZHHQWKHSXPSDQG¿OWHU
 2QLQVWDOODWLRQVZKHUHWKHZDVWHOLQHLVPRUHWKDQPHWUHVEHORZSRRO
water level and more than 12 metres in length, a vacuum break valve
PXVWEH¿WWHGLQWKHZDVWHOLQHFORVHWRWKH¿OWHU
 ,IDQDX[LOLDU\SXPSLVLQVWDOOHGLQOLQHGRZQVWUHDPRIWKH¿OWHULWVKRXOG
EHSURWHFWHGDJDLQVWFDXVLQJQHJDWLYHSUHVVXUHLQWKH¿OWHUWDQN$ÀRZ
RUSUHVVXUHVZLWFKZKLFKRQO\HQDEOHVWKHDX[LOLDU\SXPSWRUXQZKHQ
WKHPDLQ¿OWHUSXPSLVUXQQLQJZLOODFKLHYHWKLV
 ,IWKHSXPSDQG¿OWHUDUHORFDWHGEHORZSRROZDWHUOHYHOLWLVQHFHVVDU\
WR¿WLVRODWLQJYDOYHVLQWKHSLSHEHWZHHQWKHSXPSDQGWKHVNLPPHU
ER[DQGLQWKHUHWXUQSLSHIURPWKHPXOWLSRUWYDOYHWRWKHSRRO7KLV
prevents water draining from the pool during maintenance.
FAILURE TO COMPLY WITH THE ABOVE CAUTIONS MAY RESULT IN FILTER
DAMAGE NOT COVERED BY THE GUARANTEE.
Pipe Connections
8VH7HÀRQWDSHRQDOOPDOHWKUHDGV3LSLQJVKRXOGEHLQGHSHQGHQWO\VXSSRUWHGDQG
QRWLPSRVHKHDY\ORDGVRQWKH¿OWHURUSXPS8VHPPRUPP
1
/
2
” or 2”) pipe
from the pump to the skimmer box, return pipe for the multiport valve to the pool and
from the multiport valve to the drain.
DO NOT OVERTIGHTEN
7KH¿WWLQJVDQGPXOWLSRUWYDOYHRQWKLVSURGXFWDUHFRQVWUXFWHGRI
ABS. Some PVC jointing compounds are incompatible with ABS.
Check compound suitability before use.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davey CRYSTAL CLEAR and is the answer not in the manual?

Davey CRYSTAL CLEAR Specifications

General IconGeneral
BrandDavey
ModelCRYSTAL CLEAR
CategoryWater Dispenser
LanguageEnglish