A
Left installation feet
Right installation feet
Air inlet
H
W1
B
D
Air outlet
W2
Dimension drawing of outdoor unit installation
20cm Above
Space to the obstruction
10cm Above
Air in side
30cm Above
Space to the obstruction
200cm Above
Air out side
30cm Above
Connect the Outdoor Unit with Connecting Pipe:
Aim the counter-bore of the connecting pipe at the
stop valve and tighten the Taper nut with fingers.
Then tighten the Taper nut with a torque wrench.
Stop valve
Spanner
Gas side pipe
liquid side pipe
Connecting pipe
Taper nut
Install the connection pipe
When prolonging the piping, extra amount of refrigerant
must be added so that the operation and performance
of the air conditioner will not be compromised.
Not needed
≤7M
Piping length
Amount of refrigerant to be added
7- 20M
CC≤12000Btu
CC≥18000Btu
20g/m
30g/m
Note: This table is for reference only.
665(710)×420×280 430 280
Outdoor Unit Size of Shape
W1(W2)*H*D) (mm)
A (mm) B (mm)
Installation outdoor unit bolt
600(645)×485×260
400
290
660(710)×500×240
500
260
700(745)×500×255
460
260
730(780)×545×285
540 280
760(810)×545×285
540
280
800(860)×545×315
545
315
800(850)×590(690)×310
540 325
825(880)×655×310
540
335
900(950)×700×350
630
350
900(950)×795×330
535
350
790(840)×550×290
545
300
Install outdoor unit
Space to the obstruction
1.Loosen the screws and remove E-parts cover from the unit.
2.Connect the cables respectively to the corresponding terminals
of the terminal board of the outdoor unit (see the wiring diagram),
and if there are signals connected to the plug, just conduct butt joint.
3.Ground wire: Remove the grounding screw out of the electric
bracket, cover the grounding wire end onto the grounding screw
and screw it into the grounding hole.
4.Fix the cable reliably with fasteners (Pressing board).
5.Put the E-parts cover back in its original place and fasten
it with screws.
E-parts cover
1
2
L
N
Wiring Connection
Wiring diagram
Connector
If there is a connector,
connect it directly.
constant speed
Heat-pump type
Variable speed
Cooling Only
1
2(N)
1
2
3
To Indoor unit
To Indoor unit
1
2(N)
4
5
To Indoor unit
5
3
4
1
2
To Indoor unit
To Indoor unit
1(
L
)
2(N)
4(S)
Install outdoor unit
18 19
NOTE:
※ This manual usually includes the wiring mode for different kinds of A/Cs.
We cannot exclude the possibility that some special type of wiring diagrams
are not included.
※ The diagrams are for reference only. If the entity is different from this wiring
diagram, please refer to the detailed wiring diagram adhered on the unit which
you purchased.