Notes for heating
*
The fan of the indoor unit will not start running immediately after the heating is
started to avoid blowing out cool air.
*
When it is cold and wet outside, the outdoor unit will develop frost over the heat
exchanger which will compromise the heating capacity. This is when the air
conditioner will start defrost.
*
During defrost, the air conditioner will stop heating for about 5-12 minutes.
*
Vapor may come out from the outdoor unit during defrost. This is not a malfunction,
but a result of fast defrost.
* Heating will resume after defrost is complete.
Notes for turning off
* When the air conditioner is turned off, the main controller will automatically decide
whether to stop immediately or after running for dozens of seconds with lower
frequency and lower air speed.
Notices for use
The conditions of unit can't normally run
* Within the temperature range provided in following table, the air conditioner may
stop running and other anomalies may arise.
*
When the temperature is too high, the air conditioner may activate the automatic
protection device, so that the air conditioner could be shut down.
*
When the temperature is too low, the heat exchanger of the air conditioner may
freeze, leading to water leakage or other malfunction.
*
In long-term cooling or dehumidification with a relative humidity of above 80%
(doors and windows are open), there may be water condenses or dripping near
the air outlet.
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
<16℃
>30℃
<-10℃
>32℃
>52℃
* If the remote controller is lost or broken,
use force switch button to operate the
air conditioner.
* If this button is pushed with the unit OFF,
the air conditioner will operate in Auto mode.
* If this button is pushed with the unit ON,
the air conditioner will stop running.
Emergency operation
1. Use up-down swing and left-right swing
buttons on the remote controller to adjust
the airflow direction. Refer to the operation
manual of the remote controller for detail.
2. For models without left-right swing function,
the fins has to be moved manually.
Force switch
Airflow direction adjustment
Note: Move the fins before the unit is in operation,
or your finger might be injured.
Never place your hand into the air inlet or
outlet when the air conditioner is in operation.
Notices for use