User Guide
P200T
Optos Panoramic Ophthalmoscope
G102748/11_ENG

Table of Contents

Questions and Answers

  • C
    Christopher AndersonAug 4, 2025
    What to do if imaging with green patient feedback doesn't produce good results on Daytona Medical Equipment?
    • J
      Jacqueline MendezAug 4, 2025
      If imaging with the patient position feedback showing green on your Daytona Medical Equipment doesn't yield good results, it could be due to an offset in the system's virtual point, leading to incorrect feedback. To address this, try compensating by imaging with the alignment target set to red or blue, depending on what's appropriate for the situation.
  • B
    bryantmarcusAug 9, 2025
    Why can't I access the user login list on the scan head of my Daytona Medical Equipment?
    • J
      Jonathan AndersonAug 9, 2025
      If you cannot access the user login list on the scan head of your Daytona Medical Equipment, it may be due to a password error, the image server not being switched on, or the scan head not being configured with the correct image server IP address. Verify your username and password. Ensure the image server is switched on and running. Also, check the image server network address and confirm the scan head is on the same network and configured to connect to the correct address.
  • E
    Elizabeth FisherAug 14, 2025
    What to do if patient position feedback is not showing on some eyes with Daytona P200T Medical Equipment?
    • L
      Laura TranAug 14, 2025
      If the patient position feedback is NOT showing on some eyes when using Daytona Medical Equipment, it could be due to ambient lighting being too bright, an irregular pupil shape, or unmanaged ptosis. Ensure the patient’s pupil is centered on the cross hairs on the touch screen.
  • C
    Christina HarveyAug 19, 2025
    Why do optomap images show horizontal line artefacts on Daytona Medical Equipment?
    • D
      diane99Sep 12, 2025
      If optomap images from your Daytona Medical Equipment show horizontal line artefacts, it indicates that the system slit mirror requires cleaning. Contact Optos to arrange for a Field Service Engineer to clean the slit mirror.
  • J
    Jacob RileyAug 25, 2025
    How to enable capture mode on Daytona Medical Equipment?
    • B
      brian12Aug 25, 2025
      If the capture mode is disabled on your Daytona Medical Equipment, it is because the system self-test has failed. To resolve this, open the diagnostics page and run the self-test feature.
  • D
    David TownsendAug 30, 2025
    Why do optomap images show small random artefacts in fixed position on Daytona P200T?
    • S
      shawn82Aug 30, 2025
      If optomap images from your Daytona Medical Equipment show small random artefacts in a fixed position, it is likely due to dust on the main mirror or the main mirror being dirty. Use the recommended cleaning materials and procedure for cleaning the main mirror. If the issue persists contact your Optos representative.

Summary

Warnings and Cautions

General Safety Precautions

Covers safety guidance for patients with epilepsy, equipment modifications, scan head positioning, and operator safety.

Laser Safety Guidelines

Warns about potential laser injury and patient sensitivity to light.

Electrical Safety Precautions

Details electrical shock protection, applied parts, and connection precautions.

Environmental Safety Considerations

Lists environments where the device should NOT be operated.

Electromagnetic Compatibility (EMC) Safety

Discusses electromagnetic compatibility, interference potential, and corrective measures.

Cleaning and Disinfection Guidelines

Provides instructions and cautions for cleaning device parts.

Device Failure Handling

Instructions for handling device failure symptoms like noise, smoke, or burning.

Information Security Procedures

Warns against connecting unauthorized equipment and using unapproved accessories.

Data Security Best Practices

Emphasizes backup responsibility, authorized access, and protecting patient data.

Software Management on Optos PCs

Advises on installing and updating software on Optos-supplied PCs.

Symbol and Label Identification

Explains common symbols and labels used on the device and in the manual.

Introduction

Device Overview

Explains the P200T as an ultra-widefield confocal scanning laser ophthalmoscope.

Product Intended Use

Specifies the P200T's purpose for retinal imaging and autofluorescence.

Target User Profile

Defines the professional users and required qualifications for operating the device.

Operating Environment Guidelines

Specifies suitable environments for operating the device.

Device Contraindications

States that there are no known contraindications for this device.

System Components and Configuration

Outlines the necessary components and configuration of the system.

User Operations and Procedures

System Startup Procedures

Covers initial startup procedures for the system and scan head.

Daily System Power-On

Details the daily procedure for powering on the image server and scan head.

Daily System Shutdown

Procedure for properly shutting down the system at the end of the day.

Image Capture Process

Outlines the basic procedures for capturing images.

Patient Data Management

How to add or select patient records before capturing images.

Image Capture Preparation

Steps to prepare the device and patient before capturing an image.

Patient Alignment Guide

Guidance on coaching and physically aligning the patient for imaging.

Capturing SLO Images

Procedure for capturing standard SLO images.

Image Review and Analysis

Introduces tools for reviewing and annotating patient images.

System Management Functions

Covers system administration and configuration tasks.

Device Maintenance

Covers general maintenance procedures for the device.

Troubleshooting Common Issues

Provides solutions for common problems encountered with the device.

Technical Specification

IEC 60601-1 Safety Designation

Details safety classifications and compliance with IEC 60601-1 standards.

Scan Head Safety Specifications

Specifies safety designation details for the scan head.

Device Connection Ports

Describes the various connection ports on the device.

Scan Head Physical Dimensions

Provides the physical dimensions and weight of the scan head.

Review Client System Requirements

Specifies recommended settings for review client computers.

Touch Screen Specifications

Details the specifications of the touch screen display.

Table Support Requirements

Outlines the necessary specifications for the table used with the device.

Battery Information

Information regarding the device's internal battery.

Ambient Environmental Specifications

Specifies acceptable operating and storage environmental conditions.

IEC 60825-1 Laser Safety Designation

Specifies laser safety classifications according to IEC 60825-1.

Electromagnetic Compatibility (EMC) Standards

Discusses EMC standards and declarations for the device.

Contact Us

Global Headquarters Contact

Provides contact details for the global headquarters of Optos plc.

Regional Office Contacts

Lists contact information for various regional Optos offices.

Patient Alignment Guide

Daytona P200T Specifications

General IconGeneral
BrandDaytona
ModelP200T
CategoryMedical Equipment