9
5 INSTRUCTIONS FOR USE
Bridge “normally closed” inputs not used, power the control unit.
WARNING Make sure you connect the phase wire to terminal “L”
and neutral to terminal “N”.
WARNING only used thermally protected motors and with maxi-
mum 400V resonance voltage.
All control unit settings and programs are entered using the two SET
and SEL keys and indicator LED, as described below. All programming
functions can be run when the control unit is turned on or at the end
of a closing manoeuvre.
LED off LED on
LED slowly ashing LED quickly ashing
1 Selecting the number of motors
Commands Function LED status
1. Press SEL repeatedly until the “1-2MOT” LED turns on
2.
Press SET and immediately release it: the “1-2MOT” LED starts to ash indicating the currently
selected setting:
- Slow ashing = 1-motor operations;
- Fast ashing = 2-motor operations.
3. Press SEL to change the operating program type.
4. Press SET and immediately release it: the “1-2MOT” LED turns back on (new settings saved).
5.
At this point, press SEL to select any other programming function or exit programming (all LED
off).
WARNING With 1-motor operations, “FCA/SIC2” and “FCC” inputs operate as opening and closing limit switches respectively. With 2-mo-
tor operations on the other hand, the “FCA/SIC2” input acts as an input for the sensitive edge installed on door no. 2, “FCC” is not active.
In any case, bridge inputs not used to shared.
2 Built-in 433.92 Mhz receiver
2.1 Radio control learning
Commands Function LED status
1. Press SEL repeatedly until the “RADIO” LED turns on
2.
Press SET and immediately release: the “RADIO” LED starts to ash indicating the receiver
learning status.
3.
Press the radio control key to be learnt. The LED remains on for one second and then resumes
ashing (key learnt).
4. Repeat point 3 for any other keys or radio controls to be learnt.
5. Wait until the LED turns on again (learning completed).
6.
At this point, press SEL to select any other programming function or exit programming (all LED
off).
WARNING The unit automatically recognises the type of radio control at rst learning (dipswitch or rolling code) and will later only receive
other radio controls with the same encoding.
2.2 Radio control memory reset
Commands Function LED status
1. Press SEL repeatedly until the “RADIO” LED turns on.
2. Press SET and hold down until the LED starts to quickly ash (deleting).
3.
Release the SET key.
Wait until the LED turns on again (deleting completed).
4.
At this point, press SEL to select any other programming function or exit programming (all LED
off).