GHOST 200
29
DE
CON 1
7981011 12131415
16 17
18
19
20
21
22
23
24
25
26
27
28
29
33
32
2
1
4
3
6
5
ABAB
F2
FLASH
LOCK
WARNING
J5 J9
VERKABELUNG ENCODER NUR FALLS VORHANDEN
WERKSEITIGE VERKABELUNGEN
BAUSEITIGE VERKABELUNGEN
N.O.
N.O.
RG58
N.C.
START
PED
TX RX
TX RX
PHOTO 2PHOTO 1
Mot 2 (Nur falls vorhanden)
KONTROLLLEUCHTE TOR
OFFEN 24V max 15W
ELEKTROSCHLOSS
Art.110
FLASH
AURA N
max 15W
2 x 1 mm
2
2 x 1 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
3 x 1,5 mm
2
3 x 1,5 mm
2
3 x 0,22 mm
2
3 x 0,22 mm
2
N.C.
2 x 0,5 mm
2
COM
N.C.
N.O.
COM
N.C.
N.O.
230V
22V
F
N
TRANSFORMATOR
230V/22V
VERSORGUNG
230V~ 50Hz ±10%
F1
BLAU
ROT
BLAU
ROT
STOP (Nur falls notwendig)
2 x 0,5 mm
2
SAFETY (Nur falls notwendig)
BRAUN
WEIß
GRÜN
BRAUN
WEIß
GRÜN
BRAUN
WEIß
GRÜN
BRAUN
WEIß
GRÜN
ENC
M2
ENC
M1
A
Position „A” = Motoren mit Encoder (nicht vergessen, P029 auf 0 einzustellen)
B
Position „B” = Motoren ohne Encoder (nicht vergessen, P029 auf 1 einzustellen)
An Klemme 32/33 für Normalanschluss
An Klemme 1/2 für Autotest Sicherheitsvorrichtungen (P071)
COM
IN_1
COM
IN_2
COM
IN_3
COM
IN_4
COM
IN_5
COM
IN_6
Schaltplan für 24V