5 ELECTRICAL CONNECTIONS
Run the motor connections following the wiring diagrams.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the current
regulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. As
an example, if the cable is out side (outdoor), must be at least equal to H05RN-F, whereas if it (in a raceway), must be at least equal to
H05VV-F.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
WARNING Maintain the ground conductor at a major length respect the active conductors so that, if the cable exit from its xing housing,
the active conductors tighten up as rst.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,75mm
2
.
Program the control board to complete all adjustments. It is now possible to supply a complete installation in compliance with all stan-
dards required for gate automation. See the instructions provided with the control panel to be connected.
Finally, verify that all adjustments operations have been correctly performed and that safety devices and unlocking device properly
work.
Recommended values for standard “TYPE 03 - Barriers” 24V
Running speed
(P032 - P033)
Slowdown speed
(P031 - P034)
Slowdown
duration
(P035 - P036)
Soft-start
(P054)
Facilitation
release
(P057)
Stop margin
(P058 - P059)
STOP24NET/N/L-F (8 m)
65% 30% 30% 1
2
(default)
2
(default)
STOP24NET/N/L-F (6 m)
80% 30% 30% 1
STOP24NET/N/L-F (5 m)
90% 30% 30% 1
STOP24NET/N/L-F (4 m)
90% 30% 30% 0
STOP24NET/N/V-F (4 m)
100% 30% 30% 0
Recommended values for standard “TYPE 03 - Barriers” 230V
STOPNET/N/L-F (8 m)
75% 40% 20% 40% 1
2
(default)
2
(default)
STOPNET/N/L-F (6 m)
85% 30% 20% 1
STOPNET/N/L-F (5 m)
90% 30% 30% 1
STOPNET/N/L-F (4 m)
100% 25% 20% 0