No 3 Periodic checking and hints for sam-
No 3 Periodic checking and hints for sam-No 3 Periodic checking and hints for sam-
No 3 Periodic checking and hints for sam-
pling
plingpling
pling
Required tools:
91548202 Test probe for MM27BC.
89634701 MM25 / MM27BC cleaning probe
1.
1.1.
1.
The fat sampler has two O-rings and a
rubber gasket or sampler plug that must be
replaced once a year.
2.
2.2.
2.
The silicon tubes and rubber bottle holder
must be replaced before they have deteri-
orated, typically 1-2 years.
Frequency 2000h of operation
Max. interval 12 months
Estimated time: 30 min
Service type: Inspect
2
0
9
8
3
9
DeLaval milk meter MM27BC
DeLaval milk meter MM27BCDeLaval milk meter MM27BC
DeLaval milk meter MM27BC
161 Preventive maintenance
3 (22)
© DeLaval 2012.All rights reserved.
Printout from Memoviewer 11/6/2012.