Parameter 21: Reference search speed
Range : 1-100
Default : 50
Units : %
Remark : Only in combination with the encoder position measurement system.
Function
Setting of the axis speed during reference search.
Description
The search speed for the reference marker can be adjusted by programming a percentage of the
max. output voltage (10V).