Delem
V1101, 6.4
DA-max. = 185
Note: The unit indication "mm" will not be displayed on the screen (data preparation and data
editing) of the control.
Crowning device position and adjustment for non calculated purposes
When you use the non calculated crowning device the required crowning is not based on the
three machine parameters, as described before. You have to program the required value.
To be sure that the crowning device is adjusted to the programmed position. The crowning
device should be adjusted as follows:
• Go to to the auxiliary menu and program axis ‘CROWN’.
• Press ‘change parameters’.
• Program for Min. value and DA-min 0.
• Program for Max. value and DA-max 255 (standard resolution) and 1023 (high resolution).
• Move the crowning device to the mechanical minimal position by means of the handwheel or
to the position that corresponds with 0 % crowning.
• Read out the deflection value on the screen (Manual mode, manual positioning). This value
corresponds with the number of DA-points. Remember that value and program it at the end
of the adjustment procedure at the parameter DA-min.
• Now move the crowning device to the mechanical maximal position or to the position that
corresponds with 100% crowning.
• Read out the deflection value on the screen (Manual mode, manual positioning). This value
corresponds with the number of DA-points. Remember the value and program it at the end of
the adjustment procedure at the parameter DA-max.
• Program now the found DA-values to the corresponding machine parameters and program
Min. Value at 0 (read 0 %) and Max. Value at 100 (read 100 %).