EasyManua.ls Logo

Delem DA-65 - Page 176

Delem DA-65
239 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Delem
V1101, 6.6
Parameter 7: Min. value
Range : -999999.00 - +999999.00
default : -9999.00
Units : display units
Function
Minimal value of auxiliary axis in defined display units. When the axis is moved manually the
position is also limited at this value.
Description
The value of this parameter depends on the accuracy you want to have for your axis. For
calculated crowning the resolution must always be in hundreds (0.01).
The parameter ‘decimal point position’ should stay 0 (default value) in this case. See parameter
15.
Example
The axis must be programmed with a resolution of 0.01 mm. When the minimal value of the axis
is 10.00, you should program 1000.
In case of non calculated crowning the Min. Value is normally 0 (0%). Depending on the
parameter ‘Decimal point position’ this value can also be 0.0 or 0.00 or 0.000.