V1101, 7.8
Parameter 14: Default value
Range : 00000 - 11111
Default : 00000
Units : -
Function
The default value of the digital outputs - programmed in this menu - in the user screens. If the
Number of FD outputs is 3, then the range of the default value becomes automatically 000 - 111.
So, the number of digits refers to the number of digital output programmed.
Examples digital outputs
In situation 1 there is no digital R-axis and the on-off parameters should be programmed as:
- the number of digital outputs: 2
- the least significant output: 2
- default value: 00 (this can be programmed to 01, 10 or 11)
In situation 2 there is no digital R-axis and the on-off parameters should be programmed as:
- the number of digital outputs: 2
- the least significant output: 4
- default value: 00 (this can be programmed to 01, 10 or 11)
In situation 3 there are two solutions:
3a: there is no digital R-axis and the on-off parameters should be programmed as:
- the number of digital outputs: 4
- the least significant output: 1
- default value: 0000 (this can be programmed from 0000 to 1111)
3b: there is a digital R-axis and the on-off parameters should be programmed as:
- the number of digital outputs: 2
- the least significant output: 3
- default value: 00 (this can be programmed to 01, 10 or 11)