Delem
V1101, 9.7
Parameter 18: Min. AD-value
Range : 0 - 1023
Unit : -
Default : 0
Function
Minimum value of AD-converted potentiometer voltage. This value represents the minimum
angle at which the part support arm may be positioned.
Parameter 19: Max. AD-value
Range : 0 - 1023
Unit : -
Default : 1023
Function
Maximum value of AD-converted potentiometer voltage. This value represents the maximum
angle at which the part support arm may be positioned.