Delem
V1101, 9.17
Parameter AM: Adjustment mode
Range : 0 - 6
Unit : -
Default : 0
Function
When Part Support is switched on in manual mode, the user can monitor a value in the “zoomed
values” menu. With this parameter, you can program which value you want to be displayed in
that menu. There are seven possibilities:
0: Actual part support angle [°]. This is the standard setting;
1: Actual error [°];
2: Maximum error per bend [°];
3: Minimum error per bend [°];
4: Actual part support angle speed [°/s];
5: Maximum part support angle speed per bend [°/s];
6: Mean reference angle speed per bend [°/s];
Normally during operation this parameter is set to 0, but during adjustment the settings 1-6 are
useful to monitor the behaviour of the part support.