Delem
V1101, 9.36
Parameter: 14
Default value
Range : 0000 - 1111 (binary values)
Default : 0000
Unit : -
Function
Toggle on/off function for each part support unit.
Description
A “1” means that the part support axis is used for the active bending (is switched ON), “0”
means that the part support axis is not used (is switched OFF).
Example
1000 means that for a specific bending one part support axis is enabled, i.e the part support axis
on the first position.
Parameter: SA
Safety stop angle
Range : 0.0 - 90.0
Default : 0.0
Unit : degrees (E)
Function
Angle at which the part support arm is stopped in the retour movement.
Parameter: MS
Max. angle speed
Range : 0 - 255
Default : 1
Unit : degrees per second (E/s)
Function
The maximum angle speed at which the support arm can move.